background image

 

Parry

-British Built for Purpose 

IN173-4

 

  Conversion Instructions 

 

 

 

This conversion must be carried out by a competent qualified person. 
 

 

Disconnect machine from gas supply 

 

Remove cooking grids and burner covers 

 

Undo the three wing nuts on the rail that is fixing the burners in position. Once the 
rail is removed the burners can be lifted straight out. 

 

Remove the back panel by removing six screws. 

 

Unscrew the four burner injectors and replace with the appropriate injectors for the 
gas type that is being changed to (see table below) 

 

Reassemble the burners and fix the rail down with the wing nuts. 

 

Undo the pilot nut, by turning anticlockwise.  

 

Replace the pilot injector with the appropriate pilot injector for the gas type being 
changed to from the conversion kit provided 

 

Reassemble the pipe onto the pilot and tighten the nut. 

 

Reassemble the back panel, fixing in place with the six screws. 

 

Pull off the black control knobs 

 

Undo the three screws at the bottom of the fascia and remove. 

 

Alter the low rate adjuster screw on both valves accordingly 

 

Reseal the adjuster screws with paint. 

 

Replace the fascia panel and attach control knobs. 

 

Test for soundness  

 
When conversion is complete affix new data label and the appropriate gas label supplied 
with the conversion kit, detailing type of gas and pressure etc. 
 

 

 

 

 

 

Model 

Gas Input 

Injector Code 

PGC6P 

 
Propane G31 @ 37 mbar 
14.8”  W.G. 

INJECT119 

PGC6 

Natural Gas G20 @ 20 mbar 
8” W.G. 
 

INJECT193 

Summary of Contents for PGC6

Page 1: ...Instruction Manual Gas Chargrill PGC6 PGC6P...

Page 2: ......

Page 3: ...aning Instructions 7 Maintenance Instructions 8 Conversion Instructions 9 Technical Information 10 11 Fault Finding 12 Service Information 12 Exploded View 13 Parts List 13 14 Replacement Parts 15 16...

Page 4: ...ly responsive and complies with gas safety regulations This model is designed to cook using lava rock for the distinctive smoky aroma and taste The unit leads the industry in Design and aesthetic appe...

Page 5: ...Installation and Use Regulations and the Health and Safety at Work Act All commercial gas catering equipment is recommended to be mounted below an extraction canopy Please consult a ventilation engin...

Page 6: ...be blocked at any time SEE TECHNICAL DETAILS Appliances are designed to be installed on Parry Catering Equipment for stability should they be fitted on any other surface they should be suitably secure...

Page 7: ...ed such that there are no sharp bends or torsional strain which may cause damage or failure of the tube or hose especially near the end fittings Torsional strain can be prevented by using internal uni...

Page 8: ...direction through the gradients to This is the lowest setting which has been set at the factory and must not be adjusted by user To turn burner off turn knob in a clockwise direction all the way to r...

Page 9: ...y use Allow unit to cool down before cleaning Turn off gas supply Wipe down the machine with a soft cloth do not use abrasive materials Drip trays must be emptied regularly Stainless steel cleaners ma...

Page 10: ...rts For more information on buying spares visit www parry co uk parry commercial catering spares To facilitate maintenance it is recommended that the cooking grid is removed and also the lava rock tra...

Page 11: ...ut by turning anticlockwise Replace the pilot injector with the appropriate pilot injector for the gas type being changed to from the conversion kit provided Reassemble the pipe onto the pilot and tig...

Page 12: ...Total Heat Input NATURAL G20 20mb 8 W G 5 43 KW 18 527 Btu h PROPANE G31 37mb 14 8 W G 5 43 KW 18 527 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 500 17 95 PROPANE G31 0 205 7 24 0 875 0 397...

Page 13: ...otal Heat Input NATURAL G20 20mb 8 W G 1 777 KW 6 062 Btu h PROPANE G31 37mb 14 8 W G 1 976 KW 5779 Btu h Gas Rate M HR FT HR LB HR KG HR NATURAL G20 0 177 6 2467 PROPANE G31 0 081 2 855 0 340 0 154 G...

Page 14: ...ial 12 month warranty period will cause the 24 month warranty to become void If the supply cord becomes damaged it must be replaced by the manufacturer it s service agent or a similarly qualified pers...

Page 15: ...pose IN173 4 13 Exploded View Parts List Part Number Description Part No 1 Cooking Grid No Code 2 Lava Rock Grid No Code 3 False Flue No Code 4 BURNER BOX CHARBOX01 5 Chargrill Lifting Gear LCB00036 6...

Page 16: ...16 Gas Valve FSD GASTAP8 1 16a 8mm Olive OLVCOMPR8 16b Nut 8mm Tube NUTTUB8MM 17 Gas Valve Saddle Bracket BRACKET01 18 Injector INJECT130 NAT INJECT082 LPG 18a 8mm Olive Part of above 18b 8mm Compress...

Page 17: ...fitted when replacing the generator Flame safety device Spark Ignitor To replace thermocouple Undo the nut holding the thermocouple at the rear of the cock and loosen the clamping bracket at the burn...

Page 18: ...he loose spigot is pushed firmly into its housing and seat the rubber washer in the recess provided Refit the saddle bracket and the tighten the two screws Refit float rail assembly Reconnect gas feed...

Page 19: ...llation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and...

Page 20: ...Parry British Built for Purpose IN173 4 18 Disposal Recycling The packaging should be disposed of in accordance with the regulations in force...