22
Before you install the hob, make sure that
•
the work surface is made of a heat
-
resistant material.
•
if the hob is installed above an oven
,
the oven has a built
-
in cooling fan.
•
the installa
�
on complies with all clearance requirements and New Zealand standards and
regula
�
ons.
•
a suitable isola
�
ng switch providing full disconnec
�
on from the mains power supply is
incorporated in the permanent wiring
,
mounted and posi
�
oned to comply with the local
standards and regula
�
ons.
•
the isola
�
ng switch must be of an approved type and provide
a 3
mm air gap contact
separa
�
on in all poles
(
or in all ac
�
ve [phase] conductors if the local wiring rules allow for
this varia
�
on of the requirements
)
.
•
the isola
�
ng switch will be easily accessible to the customer with the hob installed.
•
consult local building authori
�
es and by
-
laws if in doubt regarding installa
�
on.
•
heat
-
resistant and easy
-
to
-
clean
fi
nishes
(
such as ceramic
�
les
)
are used for the wall
surfaces surrounding the hob.
•
the power supply cable is not accessible through cupboard doors or drawers.
•
there is an adequate
fl
ow of fresh air from outside the cabinetry to the base of the hob.
•
if the hob is installed above a drawer or cupboard space
,
a thermal protection barrier is
installed below the base of the hob.
•
the isola
�
ng switch is easily accessible.
A(mm) B(mm) C(mm) D
E
F
G
650
50 min 20 min Air intake Air e
x
it
≥
5mm >
35
mm <50mm
D
E
A
C
B
>2cm
F
G
Summary of Contents for HX-2-2NF-INDUCT
Page 2: ...727626092022 ...