47
GB/IE
Feed roll, welding nozzle and wire
cross-section must be compatible with
one another.
The device is suitable for wire reels
weighing up to maximum 1000 g.
z
Fit the gas cylinder
Note:
When screwing in the gas
cylinder
29
, you must wear gloves to
protect your hands.
First remove the plastic protective cap
by turning it in a clockwise direction
and pull it off the 0.95 litre argon gas
cylinder
29
. With the connecting thread
aligned with the pressure regulator
14
,
place the gas cylinder in the bracket
inside the device which has been
provided for this purpose, see Figur
e E.
Make sure that the retaining straps
30
go right round the gas cylinder
29
.
However, do not tighten these yet.
Make sure that the switch on the
pressure regulator
14
is set to the “Off”
position. To do this, turn the regulator on
the pressure regulator in an anti-clock-
wise direction. Now guide the connect-
ing thread of the gas cylinder
29
to the
inlet of the pressure regulator
14
. Then
connect the inert gas inlet tubing
13
to
the quick connector of the pressure reg-
ulator
27
. To do this push the inert gas
inlet tubing
13
into the quick connector
of the pressure regulator
27
until it clicks
into place. Rotate the gas cylinder
29
as
shown in Figure E, in order to connect
it to the pressure regulator
14
. When
fixing the pressure regulator
14
gas will
leak for a short time. The gas will stop
leaking once it has been connected
properly. In order to make a solid
connection, undo the bracket screw
28
of the pressure regulator
14
, if neces-
sary. Now screw the pressure regulator
14
onto the gas cylinder
29
while
holding the gas cylinder
29
, until they
are firmly connected together and there
is no gas leak. When doing this, grip
the bracket of the pressure regulator
26
and not the pressure regulator
14
itself,
in order to avoid any damage. Rotate
the pressure regulator
14
and the gas
cylinder
29
(which are now connected),
until the pressure regulator
14
is back
in a vertical position and re-tighten the
bracket screw
28
of the pressure regula-
tor
14
. Now fix the gas cylinder
29
by
tightening the retaining strap
30
.
Remove the gas cylinder
29
from the
device once the welding work is complete.
z
Adaptation of device to
flux-cored welding wire
with inert gas
The correct connections for welding with
flux-cored wire when using inert gas are
shown in Figure U.
U
7
6
9
First connect the plug
9
with the
connector marked with the “+” (see
Figure U) and rotate it in a clockwise
direction to fix it in place. If you are
in any doubt, then please contact a
professional.
Then connect the earth cable
6
with
the corresponding connector, marked
Welding with flux-cored wire