Parkside PHG 2500 D4 Operating And Safety Instructions Manual Download Page 10

 Commissioning / Troubleshooting / Maintenance, Cleaning ... / Service

DE/AT/CH

Inhaltsverzeichnis

Legende der verwendeten Piktogramme

 .........................................................Seite  6

Einleitung

 ........................................................................................................................................Seite  6

Bestimmungsgemäße Verwendung ...................................................................................................Seite  6
Ausstattung ..........................................................................................................................................Seite  6
Lieferumfang .......................................................................................................................................Seite  6
Technische Daten ................................................................................................................................Seite  7

Sicherheit

 ........................................................................................................................................Seite  7

Allgemeine Sicherheitshinweise ........................................................................................................Seite  7

Vor der Inbetriebnahme

 ....................................................................................................Seite  8

Gerät aufstellen ..................................................................................................................................Seite  8

Inbetriebnahme

 ........................................................................................................................Seite  8

Heizstufen und Ventilator ein- / ausschalten .....................................................................................Seite  8
Temperatur einstellen..........................................................................................................................Seite  9
Gerät ausschalten ..............................................................................................................................Seite  9
Überhitzungsschutz ............................................................................................................................Seite  9

Fehlerbehebung

 ........................................................................................................................Seite  10

Wartung, Reinigung und Lagerung

 .........................................................................Seite  10

Service

 ...............................................................................................................................................Seite  10

Garantie

 ...........................................................................................................................................Seite  11

Entsorgung

.....................................................................................................................................Seite  11

Original-EG-Konformitäts erklärung / Hersteller

 .........................................Seite  12

277044_par_ROWI_Heizgeblaese_content_AT.indd   5

13.07.16   08:49

GB/IE/NI 11

  Switching off the Fan Heater

 

  Turn the temperature control  3  back to MIN.

 

 To avoid heat build-up in the fan heater, allow 
the fan to run for approximately 2 minutes after-
wards, before turning the heating level switch 

2  to position 

0

.

 

 Pull out the mains plug to disconnect the heater 
from the mains supply, thus switching it off com-
pletely.

  Overheating Protection

This fan heater is equipped with overheating pro-
tection. If the fan heater overheats, it will switch off 
automatically. The fan continues to run so that rapid 
cooling is achieved. The fan heater will switch on 
again automatically once it has cooled down prop-
erly.

DE/AT/CH

Inbetriebnahme

Lüfter-Position Befindet sich der Heiz-

stufenschalter 

2

 in 

dieser Position, wird le-

diglich das Lüfterrad 

betrieben. Bringen Sie 

den Schalter in diese 

Position, wenn Sie das 

Gerät als Ventilator ver-

wenden möchten.

Heizstufe 1

Befindet sich der Heiz-

stufenschalter 

2

 in 

dieser Position, bringt 

der Industrieheizer  

eine Heizleistung von 

1500 W.

Heizstufe 2

Befindet sich der Heiz-

stufenschalter 

2

 in 

dieser Position, bringt 

der Industrieheizer  

eine Heizleistung von 

3000 W.

Hinweis:

 Das Gerät benötigt eine Anlaufzeit von 

ca. 8 Minuten. 

 Temperatur einstellen

   

Starten Sie das Gerät, indem Sie mit Hilfe des 
Heizstufenschalters 

2

 die gewünschte Heizleis-

tung einstellen.

   

Drehen Sie den Temperaturregler 

3

 im Uhrzei-

gersinn bis zum Anschlag.

   

Wurde die gewünschte Temperatur erreicht, dre-
hen Sie den Temperaturregler 

3

 so weit gegen 

den Uhrzeigersinn zurück, bis Sie ein deutliches 
Klicken hören. Ein integrierter Thermostatregler 
schaltet die Heizfunktion nun automatisch ein / aus. 
Der Ventilator läuft in dieser Zeit konstant weiter.

  Das Gerät verfügt über eine Winkeleinstellung. 

Drehen Sie zum Verstellen der Neigung an den 
seitlich angebrachten Drehknöpfen.

 Gerät ausschalten

 Drehen Sie den Temperaturregler 

3

 auf 

MIN

 

zurück.

   

Um einen Hitzestau im Gerät zu vermeiden, 
lassen Sie den Ventilator noch ca. 2 min nach-
laufen, bevor Sie den Heizstufenschalter 

2

 

auf Pos. 

0

 drehen.

   

Zum endgültigen Ausschalten des Gerätes, das 
Heizgebläse durch Ziehen des Netzsteckers 
vom Stromnetz trennen. 

 Überhitzungsschutz

Dieses Gerät ist mit einem Überhitzungsschutz aus-
gestattet. Wenn das Gerät zu heiß wird, schaltet sich 
das Heizelement automatisch aus. Der Ventilator 
läuft jedoch weiter, damit eine schnelle Abkühlung 
erreicht wird. Das Gerät schaltet sich automatisch 
wieder ein, sobald es entsprechend abgekühlt ist.

  

ACHTUNG! Überhitzung hat in der  
Regel einen Grund! Sie kann Brandge-
fahr bedeuten!

 Kontrollieren Sie, ob das Gerät seine Wärme 
ausreichend abgeben kann: Ist das Gerät ab-
gedeckt oder steht es zu dicht an einer Wand 
oder einem anderen Hindernis? Sind die Gitter 
an der Vorder- oder Rückseite frei? Wird der 
Ventilator blockiert?
 Beseitigen Sie, wenn möglich, das Problem oder 
wenden Sie sich an die Service-Hotline (siehe 
Kapitel Service).
 Auch wenn Sie keine Ursache finden können, 
aber der Überhitzungsschutz ein weiteres Mal 
auslöst, müssen Sie das Gerät ausschalten und 
sich an die Service-Hotline (siehe Kapitel  
„Service“) wenden.

Sicherheit / Vor der Inbetriebnahme / Inbetriebnahme

277044_par_ROWI_Heizgeblaese_content_AT.indd   9

13.07.16   08:49

  PLEASE NOTE: There is usually a reason 

for overheating! It can indicate a fire 
hazard!

 

 Check whether the fan heater is giving off suffi-
cient heat: Is the fan heater covered or is it too 
close to a wall or other obstruction? Is the grid 
blocked in the front or at the back? Is the fan 
blocked?

 

 Rectify the problem if possible, or contact the 
service hotline (see the section "Service").

 

 Even if you were unable to identify the cause, if 
the overheating protection is triggered a second 
time, you must switch off the fan heater and con-
tact the service hotline (see "Service" Section).

 

Troubleshooting

Fault

Possible
cause

Solution

The fan 
heater
will not 
switch on:

The mains plug
is not plugged 
in.

Insert the
mains plug in
the socket.

Socket deliver-
ing no voltage.

Check the 
house fuses.

The fan 
heater
does not 
heat up:

Heating level 
switch  2  is not
switched on.

Set the heating 
level switch  2  
to the desired 
operating 
mode.

Temperature 
control  3  
is in the MIN 
position.

Set temperature  
control  3  to 
the MAX 
position.

Faulty heating 
element.

Notify customer 
services.

   

Maintenance, Cleaning  
and Storage

 

 Always disconnect the mains plug when the fan 
heater is not in use, before cleaning or in the 
event of operating faults!

 

 Clean the fan heater only when switched off 
and cold.

 

 Make sure when cleaning that no moisture pen-
etrates into the fan heater, to avoid irreparable 
damage to the fan heater.

 

 Clean the housing with a slightly damp cloth 
and a mild detergent.

 

  Use a vacuum cleaner to remove dust from the 
safety guard.

 

 Store the heater in a dry environment.

 

Service

If any problems arise while using your ROWI 
Electronics product, please proceed as follows:

1. Contact

You can contact the ROWI Electronics Service Team
at:

ROWI Electronics GmbH

Augartenstr. 3
76698 Ubstadt-Weiher, Germany
[email protected]
Service Hotline: +800 7694 7694
free of charge from a German landline)

Summary of Contents for PHG 2500 D4

Page 1: ...the original instructions IAN 284741 IAN 277044 HEIZGEBL SE PHG 3000 D4 VDE HEIZGEBL SE Bedienungs und Sicherheitshinweise Originalbetriebsanleitung FAN HEATER Operation and Safety Notes Translation...

Page 2: ...age containing the illustrations and familiarise yourself with all functions of the device 5 13 IE NI GB Before reading fold out the page with the images and familiarise yourself with all the features...

Page 3: ...6 4 4 1 2 3 5...

Page 4: ...0 Service Seite 10 Garantie Seite 11 Entsorgung Seite 11 Original EG Konformit tserkl rung Hersteller Seite 12 Table of contents Key to the pictograms Page 6 Introduction Page 6 Intended Use Page 6 Fi...

Page 5: ...Verwendung oder Ver nderung des Ger tes gilt als nicht bestimmungsgem und birgt erhebliche Unfallgefahren F r aus bestimmungs widriger Verwendung entstandene Sch den ber nehmen wir keine Haftung Das G...

Page 6: ...eistungsaufnahme Heizstufe 1 1500W Heizstufe 2 3000W Ventilatorbetrieb 30W Schutzart IPX4 Thermostat 0 bis 40 C Feuchtigkeit keine Kondensation 5 bis 75 Abmessungen inkl Standf e ca 32 5 x 40 x 33cm B...

Page 7: ...er Weiterbenutzung des Ger tes eine neue Netzanschlussleitung durch eine autorisierte Fachkraft installieren nen Sie niemals das Geh use des Ger tes Werden spannungsf hrende Anschl sse ber hrt und ode...

Page 8: ...ly below or above a wall socket Q Q Pull the plug out of the socket in the event of malfunctions and during thunderstorms Q Q Never use the fan heater in the immediate vicinity of a bath shower or swi...

Page 9: ...Heizstufenschalters 2 die gew nschte Heizleis tung einstellen Drehen Sie den Temperaturregler 3 im Uhrzei gersinn bis zum Anschlag Wurde die gew nschte Temperatur erreicht dre hen Sie den Temperaturre...

Page 10: ...ACHTUNG berhitzung hat in der Regel einen Grund Sie kann Brandge fahr bedeuten Kontrollieren Sie ob das Ger t seine W rme ausreichend abgeben kann Ist das Ger t ab gedeckt oder steht es zu dicht an ei...

Page 11: ...parts are built into the item that are not permitted by ROWI Electronics GmbH Claims beyond the free of charge repairs such as claims for damages are not covered by the war ranty Disposal Service Gara...

Page 12: ...Directive 2014 35 EU EU Directive on Electromagnetic Compatibility 2014 30 EU EU RoHS Directive 2011 65 EU The object of the declaration described above is in conformity with Directive 2011 65 EU of t...

Page 13: ...arantie Seite 11 Entsorgung Seite 11 Original EG Konformit tserkl rung Hersteller Seite 12 Inhaltsverzeichnis Legende der verwendeten Piktogramme Seite 16 Einleitung Seite 16 Bestimmungsgem e Verwendu...

Page 14: ...losionsf hige Atmosph re Staub Dampf oder Gas Verwenden Sie das Ger t nicht im Freien Jede andere Verwendung oder Ver nderung des Ger tes gilt als nicht bestimmungsgem und birgt erhebliche Unfallgefah...

Page 15: ...arantie Seite 11 Entsorgung Seite 11 Original EG Konformit tserkl rung Hersteller Seite 12 7 DE AT CH Einleitung Sicherheit Technische Daten Eingangsspannung 220 240V Netzfrequenz 50Hz Leistungsaufnah...

Page 16: ...setzt werden um Gef hrdungen zu vermeiden Dieses Ger t kann von Kindern ab 8 Jahren und dar ber sowie von Personen mit verringerten physischen sensorischen oder mentalen F hig keiten oder Mangel an Er...

Page 17: ...destabst nde von 30cm seitlich 30cm nach oben 30cm nach hinten und 100cm nach vorne einzuhalten Stellen Sie das Ger t nicht in einer hei en nassen oder sehr feuchten Umgebung oder in der N he von bren...

Page 18: ...leis tung einstellen Drehen Sie den Temperaturregler 3 im Uhrzei gersinn bis zum Anschlag Wurde die gew nschte Temperatur erreicht dre hen Sie den Temperaturregler 3 so weit gegen den Uhrzeigersinn zu...

Page 19: ...hlung erreicht wird Das Ger t schaltet sich automatisch wieder ein sobald es entsprechend abgek hlt ist ACHTUNG berhitzung hat in der Regel einen Grund Sie kann Brandge fahr bedeuten Kontrollieren Si...

Page 20: ...m Service Hotline 800 7694 7694 kostenlos aus dem Festnetz IAN 284741 Bitte halten Sie f r alle Anfragen den Kassenbon und die Artikelnummer z B IAN 12345 als Nach weis f r den Kauf bereit Die meisten...

Page 21: ...n Sie das Produkt nicht im Hausm ll sondern ber kommunale Sammelstellen zur stofflichen Verwertung M glichkeiten zur Entsorgung des ausgedienten Ger tes erfahren Sie bei Ihrer Gemeinde oder Stadtverwa...

Page 22: ...2017 PHG3000D4 VDE052017 AT IAN 277044 HEIZGEBL SE PHG 3000 D4 VDE HEIZGEBL SE Bedienungs und Sicherheitshinweise Originalbetriebsanleitung FAN HEATER Operation and Safety Notes Translation of the or...

Reviews: