PARKSIDE PDM 300 C3
English - 13
•
Connect the 9 V block battery to the battery clip with the correct polarity
(note + and -) and insert it into the battery compartment.
•
Replace the battery compartment cover and retighten the screw you undid
before.
7. Getting started
CAUTION!
Never exceed the max. input values stated.
Switch the multimeter on by twisting the range selector switch [3] to your chosen
measurement range. The multimeter has an auto power OFF function which
works as follows:
•
If the multimeter is not used for approx. 15 minutes, a beep sounds. Another
minute later, another beep sounds and the device switches into sleep mode.
Press any button to stop it doing so.
•
To wake the multimeter up out of sleep mode, turn the range selector switch
[3] to a different measurement range or press any button.
•
In order to deactivate the auto power OFF function, proceed as follows:
When you switch on the multimeter, press and hold the SELECT button [8].
The symbol for the auto power OFF function is no longer shown on the
display [1].
•
Next time you switch the multimeter on, the auto power OFF function is active
again
and
the display [1] shows the symbol again.