PARKSIDE PDM 300 C3
English - 15
7.4 DC or AC current measurement
•
Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the 10 A connection [7] (for currents > 200 mA)
or the OUT INPUT connection [5] (for currents < 200 mA).
•
Select the range selector switch [3] to the current measurement range you
want (μA, mA or A).
If you do not know the current level, set it first to the highest measurement
range and then switch down to the lower ranges until you have a satisfactory
reading.
•
Press the SELECT button [8] to switch between direct and alternating current.
The relevant symbol is shown on the display [1].
•
Connect the measurement probes [6] in series to the object to be measured.
•
The measured reading is now shown on the display [1]. If the measured
reading is negative, a minus sign is shown in front for DC current
measurements.
7.5 Function generator
CAUTION!
Make sure that all circuit components, circuits and parts to
be measured are disconnected and discharged. Otherwise the multimeter
could get damaged.
•
Connect the black measurement cable to the COM connection [4] and the
red measurement cable to the OUT INPUT connection [5].
•
Set the range selector switch [3] to the position.
•
Connect the measurement probes [6] to the object to be measured.
The 1 kHz square wave signal is used, among other things, for checking
and repairs on headphones, amplifiers and other electronic devices and
components.
Summary of Contents for PDM 300 C3
Page 1: ......
Page 2: ......
Page 3: ...V 1 2 English 2 Dansk 25 Fran ais 47 Nederlands 73 Deutsch 96...
Page 120: ......