5.
CONNECTING TO GAS
This appliance is designed to be installed with an
appliance flexible connection only. Supply piping
should not be less than R³
/8
(³/
8
" B.S.P.). Connection is
made to the Rc½ (½" B.S.P.) female threaded entry
pipe located just below the hotplate level on the rear
left hand side of the appliance.
Check for gas soundness after connecting the gas
supply.
The gas bayonet connector must be fitted in the
shaded area indicated in Fig. 3. Take into account that
it must be possible to pull the appliance forward
sufficiently. The hose must not get caught on the
stability bracket.
IMPORTANT: FLEXIBLE TUBING USED MUST COMPLY WITH BS. 669 CURRENT EDITION. L.P.G.
FLEXIBLE CONNECTIONS MUST BE OF A TYPE SUITABLE FOR L.P.G. AND CAPABLE OF
OPERATION UP TO 50mbar AND TO CARRY A RED STRIPE, BAND OR LABEL.
NOTE: ONLY LIQUID SEALANTS CAN BE USED IN THREADED GAS CONNECTIONS. DO NOT USE
P.T.F.E. TAPE.
6.
FITTING THE BATTERY
1.
The battery holder is located on the left hand
side of the front plinth and can be viewed
through a slot between the oven and the plinth.
2.
To gain access to the battery, open the main
oven door, rotate the battery holder clockwise
(90°).
3.
Fit the new battery ensuring positive (+) terminal
is next to the (+) sign on the battery holder. See
Fig.4.
4.
Return the battery to its original position by rotating it anti-clockwise.
7.
PRESSURE TESTING
1.
The oven injector is used as the pressure test point.
Remove the oven furniture. Remove oven burner box retaining clips (one spring clip from each side)
and remove box front cover. Replace one clip back into the right hand side of the burner box.
Remove oven burner by removing the spring clip from the right hand side of the oven burner and
slide the burner off the injector whilst easing it towards the front of the appliance, taking care not to
strain the F.S.D. phial.
2.
Connect the pressure gauge to the oven injector.
3.
Check the supply pressure by turning the thermostat on and one hotplate tap full on and light the
appropriate burner.
The pressure should be either:
(i)
For Natural Gas
20mbar
(ii)
For LP.Gas
The pressure must be set to 28 mbar for use on butane or 37 mbar for use
on propane.
4.
Turn off the taps, disconnect the pressure gauge and replace oven burner and cover, ensuring that
the F.S.D. phial is correctly located into the bracket on the burner.
5.
Check operation of oven.
6
Fig.4
All dimensions in mm