PLC Usage Explained
no vehicle passes through, the gate will close
automatically after this period.
T3:
Pedestrian
timer
4 seconds This determines how far the gate opens in
pedestrian passage mode – the motor will run for
this many seconds and then stop.
T7: Loop
disable delay
3 seconds The free exit loop is disabled for this length of time
after a vehicle has passed through the photocells.
This is so that vehicles entering through the gate
do not trigger the gate to open again if they pass
over the free exit loop after passing through the
gate.
TD: Safety
stop timer
30 seconds If “safety stop mode” is
disabled
in the menu
system, then this timer sets the delay before the
gate will resume normal operation after a safety
event.
Summary of Contents for PF9500A
Page 4: ...Technical Drawing Example 3 PF9500A ...
Page 20: ...Wiring Diagram Master PF9500A ...
Page 21: ...Wiring Diagram Master PF9500A ...
Page 22: ......
Page 24: ...Loop Guide ...
Page 25: ...Loop Guide ...
Page 26: ...Loop Guide ...
Page 27: ...Loop Guide ...
Page 28: ...Loop Guide ...
Page 29: ...Loop Guide ...
Page 30: ...Master Slave Wiring Info ...