Parker PSSV32A Installation & Service Instructions Manual Download Page 5

If your RSLogic 5000 is Version 13.X:

  • Highlight the 

1738-ACNR

 under I/O configuration, right click and 

select 

New Module

.

  • Choose the 

Generic 1738

 module from the list of Allen-Bradley 

modules.

  • Enter  a  name  (optional),  an  appropriate  slot  number  and  the 

connection parameters as shown in this screen capture.

 

  • Choose 

Next

 to set 

RPI.

  • Choose 

Finish

. Notice that the 32 Point Valve Driver Module is 

now under the I/O configuration.

Step 4:  Download the Program to the Controller and  
 

Configure the PSSCCNA or 1738-ACNR Adapter.

  • Reference  pages  4-11  through  4-15    of  Rockwell  publication 

1734-UM008 for similar setup procedure.

Step 5:  Schedule I/O Module Connections

  • Reference  pages  4-15  through  4-19    of  Rockwell  publication 

1734-UM008 for similar setup procedure.

Step 6:  Access Module Data via the PSSCCNA or 1738-ACNR 
Adapter.

  • Make sure the 32 outputs of PSSV32A appear in Controller Tags.  

Use the information in the ladder logic program to access module 
data.

  • Reference pages 4-19 through 4-22 of Rockwell publication 1734-

UM008 for similar information.

Setup the 32 Point Valve Driver in EtherNet/IP

Step 1:  Load 32 Point Valve Driver EDS file to RSLinx

  • Download EDS file from www.parker.com/pneu/isysNet
  • On your computer, follow 

Start

Rockwell Software

RSLinx 

Tools

EDS Hardware Installation Tool

 to load the EDS file to 

RSLinx

Step 2:  Set IP Address for EtherNet/IP Scanner and Adapter

  • Set  IP  address  using  Rockwell  BootP/DHCP  utility  for 

EtherNet/IP  scanner  and  PSSCENA  or  1738-AENT  adapter.   
Reference  pages  3-7  through  3-10  of  Rockwell  publication 
1734-UM011  (follow

  www.rockwell.com

Support

Support 

Overview

Online manuals and literature

I/O

1734 POINT 

and  1734D  POINT  Block  I/O

  and  find  POINT  I/O  Ethernet 

Adapter User Manual) for similar information. 

Step 3:  Add EtherNet/IP Scanner and Adapter to RSLogix  
 

5000 I/O configuration. 

  • Add EtherNet/IP scanner and PSSCENA or 1738-AENT adapter 

to  I/O  configuration.    Reference  pages  4-4  to  4-8  of  Rockwell 
publication 1734-UM011 for similar information.

Step 4:  Add 32 Point Valve Driver to RSLogix 5000  
 

I/O Configuration.

If your RSLogic 5000 is Version 15.X or greater:

  • Highlight the 

PSSCENA

 under I/O configuration, right click and 

select 

New Module

.

  • Choose the 

PSSV32A

 module from the list of Parker modules.

  • Enter a name (optional) and click OK.

   Notice that the 

32 Point Valve Drive Module

 is now under I/O 

Configuration. 

isysNet 32 Point Valve Driver, Series A (PSSV32A) 

E100P

5

Summary of Contents for PSSV32A

Page 1: ...ubject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice EXTRA COPIES OFTHESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT MAINTENANCE MANUALSTHAT UTILI...

Page 2: ...s Attentions help you Identify a Hazard Avoid a Hazard Recognize the Consequence SHOCK HAZARD Labels may be located on or inside the equipment to alert people that dangerous voltage may be present BUR...

Page 3: ...ase or communication adapter Wire the 32 Point Valve Driver Following are wiring instructions for the 32 point valve driver Use the appropriate harness assembly based on your manifold wiring interconn...

Page 4: ...Tools EDS Hardware Installation Tool to load the EDS file to RSLinx Step 2 Configure the DeviceNet Scanner Subnet Reference Chapter 4 of the isysNet DeviceNet Adapters User Manual PSS UM001 for detai...

Page 5: ...oint Valve Driver EDS file to RSLinx Download EDS file from www parker com pneu isysNet On your computer follow Start Rockwell Software RSLinx Tools EDS Hardware Installation Tool to load the EDS file...

Page 6: ...Driver in Profibus Step 1 Configure Valve Driver Module in SST Profibus Configuration Utility Note SST PFB CLX is used here for example For different Profibus scanners refer to appropriate documentati...

Page 7: ...eted dup_MAC id test Device not powered check module status indicator Flashing Green Device is on line but has no connections in the established state Green Device is on line and has connections in th...

Page 8: ...rating 30g Non operating 50g Vibration IEC60068 2 6 Test Fc Operating 5g 10 to 500Hz ESD Immunity IEC 61000 4 2 6kV contact discharges 8kV air discharges Radiated RF Immunity IEC 61000 4 3 10V m with...