Follow these instructions when installing, operating, or servicing the 
product.

isysNet 32 Point Valve Driver, Series A

(PSSV32A)

The  sealed  IP67  housing  of  these  modules  requires  no  enclosure. 
(Note  that  environmental  requirements  other  than  IP67  may  require 
an  additional  appropriate  housing.) The  PSSV32A  module  is  shown 
below.
The PSSV32A valve driver module provides an interface between the 
isysNet serial bus system and the Isys valve assembly.  This module 
will always be the last module on the isysNet serial bus.  It controls 32 
digital outputs at 24VDC.  Depending on valve selection, it can control 
up to 32 single solenoid valves or 16 double solenoid valves.

   

WARNING

FAILURE  OR  IMPROPER  SELECTION  OR  IMPROPER  USE  OF THE 

PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED 

ITEMS  CAN  CAUSE  DEATH,  PERSONAL  INJURY  AND  PROPERTY 

DAMAGE.

This  document  and  other  information  from  Parker  Hannifin  Corporation, 

its subsidiaries and authorized distributors provide product and/or system 

options  for  further  investigation  by  users  having  technical  expertise.  It 

is  important  that  you  analyze  all  aspects  of  your  application,  including 

consequences  of  any  failure  and  review  the  information  concerning  the 

product or systems in the current product catalog. Due to the variety of 

operating conditions and applications for these products or systems, the 

user, through its own analysis and testing, is solely responsible for making 

the  final  selection  of  the  products  and  systems  and  assuring  that  all 

performance, safety and warning requirements of the application are met.
The  products  described  herein,  including  without  limitation,  product 

features,  specifications,  designs,  availability  and  pricing,  are  subject  to 

change  by  Parker  Hannifin  Corporation  and  its  subsidiaries  at  any  time 

without notice.

EXTRA COPIES OF THESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION 

IN EQUIPMENT / MAINTENANCE MANUALS THAT UTILIZE THESE PRODUCTS. 

CONTACT YOUR LOCAL REPRESENTATIVE.

!

Installation & Service Instructions 

E100P
isysNet 32 Point Valve Driver,  

Series A (PSSV32A)
ISSUED:  December, 2006 

Supersedes:  June, 2005

Doc.# E100P, EN# 060961, Rev. 2

Pneumatic Division

Richland, Michigan 49083

Mod

PSSV32A

Net

Fault

PSSV32A

Outputs
25- 32
Connector

Outputs
1- 24
Connector

Safety Guide

 

For more complete information on recommended application guidelines, see 
the Safety Guide section of Pneumatic Division catalogs or you can download 
the 

Pneumatic Division Safety Guide

 at: www.parker.com/safety

     WARNING

•  To  avoid  unpredictable  system  behavior  that  can  cause  personal 

injury and property damage:

•  Disconnect  electrical  supply  (when  necessary)  before  installation, 

servicing, or conversion.

•  Disconnect air supply and depressurize all air lines connected to this 

product before installation, servicing, or conversion.

•  Operate within the manufacturer’s specified pressure, temperature, 

and other conditions listed in these instructions.

•  Medium  must  be  moisture-free  if  ambient  temperature  is  below 

freezing.

•  Service according to procedures listed in these instructions.
•  Installation,  service,  and  conversion  of  these  products  must  be 

performed  by  knowledgeable  personnel  who  understand  how   
pneumatic products are to be applied.

•  After installation, servicing, or conversion, air and electrical supplies 

(when necessary) should be connected and the product tested for 
proper  function  and  leakage.  If  audible  leakage  is  present,  or  the 
product does not operate properly, do not put into use.

•  Warnings and specifications on the product should not be covered by 

paint, etc. If masking is not possible, contact your local representative 
for replacement labels.

!

Summary of Contents for PSSV32A

Page 1: ...ubject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice EXTRA COPIES OFTHESE INSTRUCTIONS ARE AVAILABLE FOR INCLUSION IN EQUIPMENT MAINTENANCE MANUALSTHAT UTILI...

Page 2: ...s Attentions help you Identify a Hazard Avoid a Hazard Recognize the Consequence SHOCK HAZARD Labels may be located on or inside the equipment to alert people that dangerous voltage may be present BUR...

Page 3: ...ase or communication adapter Wire the 32 Point Valve Driver Following are wiring instructions for the 32 point valve driver Use the appropriate harness assembly based on your manifold wiring interconn...

Page 4: ...Tools EDS Hardware Installation Tool to load the EDS file to RSLinx Step 2 Configure the DeviceNet Scanner Subnet Reference Chapter 4 of the isysNet DeviceNet Adapters User Manual PSS UM001 for detai...

Page 5: ...oint Valve Driver EDS file to RSLinx Download EDS file from www parker com pneu isysNet On your computer follow Start Rockwell Software RSLinx Tools EDS Hardware Installation Tool to load the EDS file...

Page 6: ...Driver in Profibus Step 1 Configure Valve Driver Module in SST Profibus Configuration Utility Note SST PFB CLX is used here for example For different Profibus scanners refer to appropriate documentati...

Page 7: ...eted dup_MAC id test Device not powered check module status indicator Flashing Green Device is on line but has no connections in the established state Green Device is on line and has connections in th...

Page 8: ...rating 30g Non operating 50g Vibration IEC60068 2 6 Test Fc Operating 5g 10 to 500Hz ESD Immunity IEC 61000 4 2 6kV contact discharges 8kV air discharges Radiated RF Immunity IEC 61000 4 3 10V m with...

Reviews: