PHastkrimp Crimper Electrical Requirements, 3 Phase
The power supply should be brought to a separate branch circuit, single-grounded receptacle. The PHastkrimp
unit has been shipped with a 6 ft. long cord without a plug. Machine is shipped without a plug so local
requirements may be satisfied.
Motor Rotation – Jog the motor once and verify that the direction of rotation is the same as the arrow decal
located on the motor (counter-clockwise when viewed from fan end of motor). If motor rotation is incorrect,
disconnect power and reverse two of the three power leads (L1, L2, L3) at the plug. THESE CHANGES MUST
ONLY BE MADE BY A QUALIFIED ELECTRICIAN.
Model
89C-061
Phase
3 phase
Voltage
230
Cycle
60 Hz
Full Load Amperes
8 amps
Circuit Fuse
20 amps
Wire size for receptacle must conform to the requirements of the National Electrical Code or the prevailing local
code. The outlet box should be located within the range of the provided cord. We strongly recommend against
the use of an extension cord. The installer must perform a ground continuity check on the power outlet box
to ensure it is properly grounded.
Alternate Motor Voltages:
Reference motor nameplate.
Model number 89C-061 comes equipped with a dual-voltage motor. This model may be rewired to operate at
higher voltage by a qualified electrician.
Changing the operating voltage requires rewiring at the motor and the control circuit transformer.
THESE CHANGES MUST ONLY BE MADE BY A QUALIFIED ELECTRICIAN.
Electrical Requirements
www.comoso.com