Page 7 /15
P2M2HBVT12400
User Manual
30060921401W05
February 2018
Pneumatic Division
27031 Evreux - France
P2M Node 24DO addressing used with H Universal ISO Series
–
15407-2 & 5599-2
The P2M Node 24DO used with H ISO Series
–
15407-2
–
sizes 02 & 01 and 5599-2
–
sizes 1, 2 & 3
–
can
handle up to 24 pilot solenoid valves. Addressing is as shown below (on H Universal manifold):
Byte 1
EV08 . . . . . . . . . . . . . . EV01
0
7
PLC Process outputs data mapping
Byte 2
EV16 . . . . . . . . . . . . . . EV09
Byte 3
EV24 . . . . . . . . . . . . . . EV17
. . . . . . . . . . . . . . . . . . . . .
P2M Node 24DO Electrical Connections
Network Communication and Auxiliary power connection
Network Communication
: Standard Female M12 D-Coded connectors
–
4 pins
Auxiliary Power Supply:
Standard Male M12 A-Coded connector
–
4 pins
Use of standard manufactured cables available from usual electrical supplier is recommended.
Out
In
Power
The P2M Node 24DO Auxiliary Power for valves can be supplied from a SAFE 24Vdc auxiliary source in PP or PM mode, as well
as from Output Switching Signals Device Failsafe Digital Outputs (OSSD FDO).
P2M Node 24DO connected to SAFE power supply for Auxiliary Power
Note :
Please check max. power available from the source. Refer to the
“
Auxiliary power consumption calculation
”
section
Auxiliary Power M12 A-Coded
PIN #
Description
1
Logic Power +
2
AUX Power -
3
Logic Power -
4
AUX Power +
Network In & Out M12 D-Coded
PIN #
Description
1
2
3
TxData -
4
RxData -