Page 6 /15
P2M2HBVT12400
User Manual
30060921401W05
February 2018
Pneumatic Division
27031 Evreux - France
Byte 2
EV24 . . . . . . . . . . . . . . EV17
Solenoid Pilots addressing and Process Data mapping
P2M Node 24DO addressing used with Moduflex Valve System
The P2M Node 24DO used with Moduflex Valve System can handle up to 19 pilot solenoid valves. Addressing
is as shown below:
P2M Node 24DO addressing used with H Micro Valve Series
The P2M Node 24DO used with H Micro Valve Series can handle up to 24 pilot solenoid valves. Addressing is
as shown below:
Byte 1
EV08 . . . . . . . . . . . . . . EV01
PLC Process outputs data mapping
Byte 2
EV16 . . . . . . . . . . . . . . EV09
Byte 3*
EV24 . . . . . EV20
EV19 ... EV17
* Byte 3 / Bits 3 to 7 are not connected to valves with Moduflex Valve Range
Byte 1
EV08 . . . . . . . . . . . . . . EV01
0
7
PLC Process outputs data mapping
Byte 2
EV16 . . . . . . . . . . . . . . EV09
Byte 3
EV24 . . . . . . . . . . . . . . EV17
. . . . . . . . . . . . . . . . . . . . .
EV01 EV02 EV03
EV04
EV05 EV06 EV07 EV08 EV09
EV10 EV11 EV12 EV13 EV14
EV15 EV16 EV17 EV18 EV19
EV01 EV02
EV03
EV04
EV05 EV06
EV09
EV10
EV11
EV12
EV13
EV14
EV15
EV16
EV17 EV18
EV07
EV08
EV20 EV19
EV21 EV22
EV24 EV23
Double Address
Manifold
Single Address
Manifold
Single Address
Manifold
Double Address
Manifold