background image

8

www.parker.com/euro_pneumatic

X

The first service is due after approximately 500 hours of operation. After 
the first service, the service interval is determined by the degree of vane 
wear*. The table below shows new dimensions and the minimum 
dimensions of worn vanes.

The following normal service intervals should be applied to in 
order to guarantee problem-free operation in air motors working 
continuously at load speeds.  

Intermittent lubrication-free operation of motors with 
standard vanes, option 0

Duty cycle : 

 

 

70%

Max. duration of intermittent use : 

15 minutes

Filtering 40 µm : 

 

 

750 hours of operation*

Filtering 5 µm : 

 

 

1,000 hours of operation*

Continuous lubricated operation of motors with standard 
vanes, option 0 

Duty cycle : 

 

 

Continuous

Quantity of oil : 

 

 

1 drop per m

3

 of air

Filtering 40 µm : 

 

 

1,000 hours of operation* 

Filtering 5 µm : 

 

 

2,000 hours of operation*

Note! After 1000 hours of operation, the grease in the planetary 
gearbox must be changed

Continuous lubrication-free operation of motors equipped 
with vanes, option C

Duty cycle : 

 

 

Continuous

Filtering 40 µm : 

 

 

750 hours of operation* 

Filtering 5 µm : 

 

 

1,000 hours of operation*

*  The specified hours of operation apply when  
  the motor is running at the speed corresponding  
  to maximum power (load speed).
  This is approximately half free speed.If the motor  
  operates at higher speeds, the service interval
  is shorter.If the motor operates at lower speeds,  
  the service interval is longer.

Air motor

Dimensions on new vanes X (mm), type of vanes

Standard

Z

C

M

P1V-S002

3.3

-

-

-

P1V-S003

X

-

-

-

P1V-S008

4.3

-

-

-

P1V-S012

4.2

4.2

4.2

4.2

P1V-S020

6.5

6.0

6.0

6.0

P1V-S028

X

X

X

X

P1V-S030

6.8

6.2

6.8

6.2

P1V-S057

X

X

X

X

P1V-S060

9.0

9.0

9.0

9.0

P1V-S086

X

X

X

X

P1V-S090

X

X

X

X

P1V-S120

14.7

14.0

14.0

14.0

Air motor

Dimensions on vanes X (mm), type of vanes

Standard

Z

C

M

P1V-S002

3.0

-

-

-

P1V-S003

X

-

-

-

P1V-S008

4.0

-

-

-

P1V-S012

3.3

3.3

3.3

3.3

P1V-S020

5.8

5.3

5.3

5.3

P1V-S028

X

X

X

X

P1V-S030

6.0

5.2

6.0

5.2

P1V-S057

X

X

X

X

P1V-S060

6.0

6.0

6.0

6.0

P1V-S086

X

X

X

X

P1V-S090

X

X

X

X

P1V-S120

14.2

13.5

13.5

13.5

9.  Lubrication and service life

Summary of Contents for P1V-S

Page 1: ...the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex are...

Page 2: ...apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Improper...

Page 3: ...erature of 135 C Motor should be tested to ensure that the permissible temperature does not exceed 130 C there is a safety margin of 5 C This is the maximum permissible surface temperature of the moto...

Page 4: ...utch etc have to be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470...

Page 5: ...make sure that the flow pressure at the motor connection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces t...

Page 6: ...ure in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch I This check list shows...

Page 7: ...for the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectanc...

Page 8: ...t be changed Continuous lubrication free operation of motors equipped with vanes option C Duty cycle Continuous Filtering 40 m 750 hours of operation Filtering 5 m 1 000 hours of operation The specifi...

Page 9: ...operation For motors Order code P1V S002A P1V 6 446083A P1V S003A P1V 6 446083A P1V S008A P1V 6 446084A P1V S012A0 D0 to serial no 948688 9121720601 P1V S012A0 D0 from serial no 948689 9121720636 P1V...

Page 10: ...0620 P1V S120A 110 9121720620 P1V S120A 078 9121720621 P1V S120A 032 9121720621 P1V S120A 012 9121720621 Service kits for brake module for motors with brakes For motors Order code P1V S020AD and P1V S...

Page 11: ...1V S motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable directives Machinery Directive essential health and safety req...

Page 12: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Page 13: ...s the ambient temperature as specified in the technical data in the catalogue at all times 3 Are you certain that the P1V S motor is adequately ventilated and that no additional heat is added for exam...

Page 14: ...eich clamping area 119 13 5 17 e8 17 11 5 3 5 6 5 4 k6 10 8 e8 1 1 measuring point for temperature measurement Motor P1V S002A0130 Motor P1V S002A0095 Motor P1V S008A0190 Motor P1V S008A0130 1 measuri...

Page 15: ...5 K 80 C Maximum permitted surface temperature on the motor in atmospheres containing potentially explosive dust X Note special conditions Test certificate number IBExU04ATEXB004 X from IBExU Institu...

Page 16: ...0 parker easteurope parker com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00...

Reviews: