background image

3

www.parker.com/euro_pneumatic

F

ax

a

F

rad

4.2  Maximum Allowable Shaft Load on the Drive  
 Shaft

4. Structure

4.1  Basic Design Criteria for Air-Operated Gear  
 Motors

(planetary) gearing

air-operated vane motor

F

ax

  = axial force

F

rad

  = radial force

Illustration 1 - Axial and radial force on parallel key shaft 

4.4 Nomenclature

Communauté Européenne = European Community
This symbol documents the declaration of the
manufacturer that the required EC-guidelines – as stated 
in the EC-Declaration of Conformity - are observed and its 
provisions are followed.

This air motor is suited for standard use in 
Ex-areas.

Design Group: this motor is NOT designed for use in 
underground mining.

Design Category: this motor is designed for the use in 
areas where occasionally explosive atmospheres may 
exist, which consist of gases, steam, combustible fumes 
or a combination of dust and air (Zone 1 and Zone 21).

This motor is suited for the use in Ex areas, which are 
caused by combustible gases, steams, fumes or dust.

Ignition Protection: structural protection

Explosion Group: This motor is suited for the requirements 
per Explosion Group IIC. It also fulfills the requirements of 
the Explosion Groups IIB and IIA.

Temperature Class:

 

T6 = 85°C surface temperature
A motor with a temperature class of T6 may not exceed a 
maximum surface temperature of 85°C. Motor should be 
tested to ensure that the permissible temperature does not 
exceed 80°C; there is a safety margin of 5°C.

This is the maximum permissible surface temperature of 
the motor if used in an explosive atmosphere containing 
dust.

Temperature Class:

T5 = 100°C surface temperature
A motor with a temperature class of T5 may not exceed a 
maximum surface temperature of 100°C. Motor should be 
tested to ensure that the permissible temperature does not 
exceed 95°C; there is a safety margin of 5°C.

This is the maximum permissible surface temperature of 
the motor if used in an explosive atmosphere containing 
dust.

Temperature Class:

T4 = 135°C surface temperature
A motor with a temperature class of T4 may not exceed a 
maximum surface temperature of 135°C. Motor should be 
tested to ensure that the permissible temperature does not 
exceed 130°C; there is a safety margin of 5°C.

This is the maximum permissible surface temperature of 
the motor if used in an explosive atmosphere containing 
dust.

„Observe special requirements“ In the Operating 
Instruction Booklet marked with the symbol

II 2 GD c IIC T4 (135

o

C) X

Example:

II

2

GD

c

IIC

T6

(80°C)

T5

(95°C)

T4

(130°C)

X

Order code

Fax [N]

Frad [N]

a [mm]

P1V-S002A0130

140

180

6

P1V-S002A0095

140

180

6

P1V-S003B0100

140

180

6

P1V-S008A0Q00

200

220

7

P1V-S008A0700

200

220

7

P1V-S008A0190

200

220

7

P1V-S008A0130

200

220

7

P1V-S012A0N00

380

160

9

P1V-S012A0550

380

160

9

P1V-S012A0360

380

160

9

P1V-S012A0140

380

160

9

P1V-S012A0090

380

160

9

P1V-S012A0060

380

160

9

P1V-S012A0010

380

160

9

P1V-S020A0E50

570

720

12

P1V-S020A0460

570

720

12

P1V-S020A0240

570

720

12

P1V-S020A0140

570

720

12

P1V-S020A0070

570

720

12

P1V-S020A0032

570

720

12

P1V-S020A0018

570

720

12

P1V-S020A0005

570

720

12

P1V-S020A0002

570

720

12

P1V-S020A0001

570

720

12

P1V-S020A00005

570

720

12

P1V-S030A0E50

570

1130

14

P1V-S030A0460

570

1130

14

P1V-S030A0240

570

1130

14

P1V-S030A0140

570

1130

14

P1V-S030A0060

790

1070

15

P1V-S030A0034

790

1070

15

P1V-S030A0023

790

1070

15

P1V-S030A0018

790

1070

15

P1V-S030A0010

790

1070

15

P1V-S030A0005

790

1070

15

P1V-S060A0E00

1110

1300

15

P1V-S060A0350

1110

1300

15

P1V-S060A0270

1110

1300

15

P1V-S060A0170

1110

1300

15

P1V-S060A0063

1110

1300

15

P1V-S060A0048

1130

2090

18

P1V-S060A0030

1130

2090

18

P1V-S060A0015

1130

2090

18

P1V-S090A0C00

1110

1300

15

P1V-S090A0350

1110

1300

15

P1V-S090A0270

1110

1300

15

P1V-S090A0170

1110

1300

15

P1V-S090A0063

1110

1300

15

P1V-S090A0048

1130

2090

18

P1V-S090A0030

1130

2090

18

P1V-S120A0900

2330

2260

18

P1V-S120A0250

2330

2260

18

P1V-S120A0110

2330

2260

18

P1V-S120A0070

2330

2700

30

P1V-S120A0032

2330

2700

30

P1V-S120A0020

2330

2700

30

P1V-S028A0017

1500

3500

21

P1V-S028A0008

1500

3500

21

P1V-S028A0005

1500

3500

21

P1V-S028A0003

1500

3500

20

P1V-S028A0002

1500

3500

20

P1V-S057A0015

1500

3500

21

P1V-S057A0011

1500

3500

21

P1V-S057A0007

1500

3500

21

P1V-S057A0004

1500

3500

22.5

P1V-S086A0015

1500

3500

21

P1V-S086A0011

1500

3500

21

P1V-S086A0007

1500

3500

21

P1V-S086A0004

1500

3500

22.5

Summary of Contents for P1V-S

Page 1: ...the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex are...

Page 2: ...apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Improper...

Page 3: ...erature of 135 C Motor should be tested to ensure that the permissible temperature does not exceed 130 C there is a safety margin of 5 C This is the maximum permissible surface temperature of the moto...

Page 4: ...utch etc have to be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470...

Page 5: ...make sure that the flow pressure at the motor connection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces t...

Page 6: ...ure in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch I This check list shows...

Page 7: ...for the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectanc...

Page 8: ...t be changed Continuous lubrication free operation of motors equipped with vanes option C Duty cycle Continuous Filtering 40 m 750 hours of operation Filtering 5 m 1 000 hours of operation The specifi...

Page 9: ...operation For motors Order code P1V S002A P1V 6 446083A P1V S003A P1V 6 446083A P1V S008A P1V 6 446084A P1V S012A0 D0 to serial no 948688 9121720601 P1V S012A0 D0 from serial no 948689 9121720636 P1V...

Page 10: ...0620 P1V S120A 110 9121720620 P1V S120A 078 9121720621 P1V S120A 032 9121720621 P1V S120A 012 9121720621 Service kits for brake module for motors with brakes For motors Order code P1V S020AD and P1V S...

Page 11: ...1V S motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable directives Machinery Directive essential health and safety req...

Page 12: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Page 13: ...s the ambient temperature as specified in the technical data in the catalogue at all times 3 Are you certain that the P1V S motor is adequately ventilated and that no additional heat is added for exam...

Page 14: ...eich clamping area 119 13 5 17 e8 17 11 5 3 5 6 5 4 k6 10 8 e8 1 1 measuring point for temperature measurement Motor P1V S002A0130 Motor P1V S002A0095 Motor P1V S008A0190 Motor P1V S008A0130 1 measuri...

Page 15: ...5 K 80 C Maximum permitted surface temperature on the motor in atmospheres containing potentially explosive dust X Note special conditions Test certificate number IBExU04ATEXB004 X from IBExU Institu...

Page 16: ...0 parker easteurope parker com NL The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00...

Reviews: