background image

8

www.parker.com/euro_pneumatic

X

*  The following normal service intervals should be applied to in  
  order to guarantee problem-free operation in air motors working  
  at load speeds. The specified hours of operation apply when the  
  motor is running at the speed corresponding to maximum power
  (load speed). This is approximately half free speed. If the motor
  operates at higher speeds, the service interval is shorter. If the
  motor operates at lower speeds, the service interval is longer.

Service kits

The following kits are available for the basic motors, consisting of 
vanes and (springs).

Service kits, vanes for intermittent lubrication operation, 
option "0"

For motors 

Order code

P1V-M020 

P1V-6/4462971A

P1V-M040 

P1V-6/4462981A

P1V-M060 

P1V-6/4462991A

P1V-M090 

P1V-6/4449171A

P1V-M120 

P1V-6/4449181A

Service kits, vanes for intermittent lubrication operation, 
option "Z"

For motors 

Order code

P1V-M020 

P1V-6/4449144B

P1V-M040 

P1V-6/4449154B 

P1V-M060 

P1V-6/4449164B 

P1V-M090 

P1V-6/4449174B

 

P1V-M120 

P1V-6/4449184B

Lubrication and service life

The first service is due after approximately 500 hours of operation. After 
the first service, the service interval is determined by the degree of vane 
wear*. The table below shows new dimensions and the minimum di-
mensions of worn vanes.

Spare parts Order Code

Motor

Air Motor (1)

Gear Box (2)

P1V-M020C0230

P1V-M/202193A

P1V-M/202202B

P1V-M020C0146

P1V-M/202193A

P1V-M/202202D

P1V-M020C0054

P1V-M/202193A

P1V-M/202202G

P1V-M020C0034

P1V-M/202193B

P1V-M/202202C

P1V-M020C0021

P1V-M/202193B

P1V-M/202202E

P1V-M020C0012

P1V-M/202193B

P1V-M/202202F

P1V-M020C0008

P1V-M/202193B

P1V-M/202202H

P1V-M020C0003

P1V-M/202193B

P1V-M/202202I

Motor

Air Motor (1)

Gear Box (2)

P1V-M040C0230

P1V-M/202194A

P1V-M/202202B

P1V-M040C0146

P1V-M/202194A

P1V-M/202202D

P1V-M040C0054

P1V-M/202194A

P1V-M/202202G

P1V-M040C0034

P1V-M/202194B

P1V-M/202202C

P1V-M040C0021

P1V-M/202194B

P1V-M/202202E

P1V-M040C0012

P1V-M/202194B

P1V-M/202202F

P1V-M040C0008

P1V-M/202194B

P1V-M/202202H

Motor

Air Motor (1)

Gear Box (2)

P1V-M060C0230

P1V-M/202179A

P1V-M/202202B

P1V-M060C0146

P1V-M/202179A

P1V-M/202202D

P1V-M060C0054

P1V-M/202179A

P1V-M/202202G

P1V-M060C0034

P1V-M/202179B

P1V-M/202202C

P1V-M060C0021

P1V-M/202179B

P1V-M/202202E

P1V-M060C0012

P1V-M/202179B

P1V-M/202202F

Motor

Air Motor (1)

Gear Box (2)

P1V-M090C0245

P1V-M/202409A

P1V-M/807015B

P1V-M090C0156

P1V-M/202409B

P1V-M/807015C

P1V-M090C0058

P1V-M/202409A

P1V-M/807015D

P1V-M090C0036

P1V-M/202409B

P1V-M/807015E

P1V-M090C0023

P1V-M/202409B

P1V-M/807015F

P1V-M090C0013

P1V-M/202409A

P1V-M/807015G

P1V-M090C0009

P1V-M/202409B

P1V-M/807015H

P1V-M090C0004

P1V-M/202409B

P1V-M/807015I

Motor

Air Motor (1)

Gear Box (2)

P1V-M120C0245

P1V-M/202457A

P1V-M/807015B

P1V-M120C0156

P1V-M/202457B

P1V-M/807015C

P1V-M120C0058

P1V-M/202457A

P1V-M/807015D

P1V-M120C0036

P1V-M/202457B

P1V-M/807015E

P1V-M120C0023

P1V-M/202457B

P1V-M/807015F

Air motors  

Dimensions  

Minimum dimensions 

 

on new vanes 

on vane 

 

X [mm] 

 

X [mm]

P1V-M020

 

 

8,5 

 

 6,5

P1V-M040

 

 

7,0 

 

 5,0

P1V-M060

 

 

8,0 

 

 6,0

P1V-M090

   

 

 X

P1V-M120

   

 

 X

Spare parts

For motor with Z optional option, please consult factory

(2)

(1)

Summary of Contents for P1V-M Series

Page 1: ...r the surrounding area Important instructions relating to explosion protection Application tips and other useful information Definition Potentially explosive atmosphere hereinafter referred to as Ex a...

Page 2: ...ons apply Warranty and liability claims in regards to persons or equipment damage are invalid if one or several of the following causes apply Use of the equipment in a non designated application Impro...

Page 3: ...or should be tested to ensure that the permissible temperature does not exceed 95 C there is a safety margin of 5 C This is the maximum permissible surface temperature of the motor if used in an explo...

Page 4: ...e to be covered by a contact guard 8 8 0 72 1 28 2 9 5 75 9 9 24 48 83 132 200 275 390 10 9 1 02 1 8 4 1 8 1 14 34 67 117 185 285 390 550 12 9 1 21 2 15 4 95 9 7 16 5 40 81 140 220 340 470 660 70 0 46...

Page 5: ...nnection side is 6 bar 85 PSI A higher air pressure leads to increased wear and tear install a pressure regulator An air pressure below 6 bar reduces the power output of the motor Lubrication All moto...

Page 6: ...bient temperature in accordance 5 3 with requirements Has it been certified that the air motor is sufficiently ventilated and that there is no 5 5 additional warming source such as a clutch Is a forma...

Page 7: ...r the disassembly original spare parts and the trained repair specialists that can adjust the air motor to the correct gap play The gap play determines the motors power efficiency and life expectancy...

Page 8: ...M020C0034 P1V M 202193B P1V M 202202C P1V M020C0021 P1V M 202193B P1V M 202202E P1V M020C0012 P1V M 202193B P1V M 202202F P1V M020C0008 P1V M 202193B P1V M 202202H P1V M020C0003 P1V M 202193B P1V M 20...

Page 9: ...ion hole Step 4 Remove the old vane and replace it with a new one Repeat steps 3 and 4 until all the vanes have been replaced Step 5 Replace the inspection plug Step 6 Replace the rear piece Replacing...

Page 10: ...hey do not usually carry the CE mark Nevertheless most P1V M motors carry the CE mark because they are ATEX certified for use in explosive atmospheres The following are the currently applicable direct...

Page 11: ...and of motor bearing cover Air pressure is Increase air too low pressure No air shut off Open shut off valve is closed valve Hose diameter Use a hose with a is too small larger diameter Exhaust air i...

Page 12: ...The Netherlands Oldenzaal Tel 31 0 541 585 000 parker nl parker com NO Norway Asker Tel 47 66 75 34 00 parker norway parker com PL Poland Warsaw Tel 48 0 22 573 24 00 parker poland parker com PT Portu...

Reviews: