15

Bulletin HY22-3220A/US

Instruction Manual

550 Series Hydraulic Power Units

Performance Data

550 Power Units @ 1725 RPM

17

14

20

07

04

10

(500)

(3000)

(2500)

(2000)

(1500)

(1000)

(50)

(100)

(150)

(200)

(250)

(300)

(350)

0.8

1.6

2.5

3.3

4.1

4.9

5.7

(400)

6.6

Output Flow - 

lpm

 (cipm)

0

34

69

103

138

172

207

Operating Pressure - bar 

(psi)

0

550 Power Units @ 3450 RPM

17

14

20

07

04

10

(500)

(3000)

(2500)

(2000)

(1500)

(1000)

(100)

(200)

(300)

(400)

(500)

(600)

(700)

1.6

3.3

4.9

6.6

8.2

9.8

11.5

(800)

13.1

Output Flow -

 lpm 

(cipm)

0

34

69

103

138

172

207

Operating Pressure - bar (psi) 

0

Motor Horsepower Recommendations at Flow/Pressure

Pump 

Size

Nominal GPM

Pressure Bar (PSI)

@1725

@3450

34

(500)

69

(1000)

103

(1500)

138

(2000)

172

(2500)

207

(3000)

04

¼

.50 HP

.50 HP

.50 HP

.50 HP

.50 HP

.50 HP

04

½

.50 HP

.50 HP

.50 HP

.75 HP

1.0 HP

1.0 HP

07

½

.50 HP

.50 HP

.50 HP

.75 HP

1.0 HP

1.0 HP

07

1

.50 HP

.75 HP

1.0 HP

1.5 HP

2.0 HP

2.0 HP

10

¾

.50 HP

.50 HP

.75 HP

1.0 HP

1.5 HP

1.5 HP

10

1 ½

.75 HP

1.0 HP

1.5 HP

2.0 HP

3.0 HP

3.0 HP

14

1

.50 HP

.75 HP

1.0 HP

1.5 HP

2.0 HP

2.0 HP

14

2

1.0 HP

1.5 HP

2.0 HP

3.0 HP

17

1 ¼ 

.50 HP

1.0 HP

1.5 HP

2.0 HP

2.0 HP

17

2 ½ 

1.0 HP

2.0 HP

3.0 HP

20

1 ½ 

.50 HP

1.0 HP

1.5 HP

2.0 HP

20

3

1.0 HP

2.0 HP

3.0 HP

Note: 

Performance data is for reference only

Performance data based on ATF @ 21°C (70°F)

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Summary of Contents for Oildyne 550 Series

Page 1: ...Oildyne 550 Series Hydraulic Power Units Bulletin HY22 3220A US Instruction Manual Effective August 01 2011 416181...

Page 2: ...sible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems Offer of Sale Please contact your...

Page 3: ...se see pages 7 and 8 The life expectancy of Parker Oildyne power units is directly tied to the frequency of use the product in which it is incorporated and the application Shipping weights for the 550...

Page 4: ...11 80 88 9 3 50 87 4 3 44 171 5 6 75 135 1 5 32 SINGLE PHASE ONLY FILLER BREATHER 101 6 169 1 4 00 6 50 65 0 2 56 182 1 MAX 7 17 165 1 6 50 76 2 3 00 62 0 2 44 62 0 2 44 4X 8 6 34 SLOT 4 LITER 5 6 LIT...

Page 5: ...TR THD O RING PORTS P T 304 8 12 00 1 GAL 4 LITER 406 4 16 00 1 1 2 GAL 5 6 LITER 101 3 3 99 24 1 0 95 140 4 5 53 MOTOR HEIGHT 237 2 299 7 9 34 11 80 SINGLE PHASE ONLY FILLER BREATHER RELIEF VALVE RET...

Page 6: ...10 00 304 8 12 00 25 8 1 02 171 5 6 75 598 8 23 58 311 3 12 26 51 3 2 02 131 8 5 19 63 6 2 51 58 6 2 31 231 6 9 12 66 8 2 63 82 6 3 25 39 9 1 57 93 5 3 68 215 9 8 50 181 7 13 GAUGE PORT LOCATION SAE 6...

Page 7: ...Instruction Manual 550 Series Hydraulic Power Units Power Unit Schematics Hydraulic Schematics P T P T P T P T SA CIRCUIT SW CIRCUIT S1 S4 P1 P4 CIRCUITS S5 S8 P5 P8 CIRCUITS Parker Hannifin HPS Divis...

Page 8: ...NSATED FLOW CONTROL F1 OR F2 S5 S8 P5 P8 CIRCUITS WITH PRESSURE COMPENSATED FLOW CONTROL F1 OR F2 D0 CIRCUIT D03 VALVE TO BE SELECTED D1 CIRCUIT INCLUDES MANAPAK DUAL P0 CHECK VALVE D03 VALVE TO BE SE...

Page 9: ...s Power Units are complete assemblies A small portion is created without the electric motors allowing the customer to purchase and install alternate motors There is a C face kit available Oildyne part...

Page 10: ...most mineral based hydraulic fluids with viscosities between 32 cSt 150 SSU and 64 cSt 300 SSU at 38 C 100 F For fluids other than these please contact Oildyne Division with the details If users wish...

Page 11: ...ted emissions should be performed in accordance with the Electromagnetic Compatibility EMC Generic Emissions standards for environments appropriate to the end use product to confirm compliance with th...

Page 12: ...sed Conduit Connector S3 120 VAC Normally Closed Conduit Connector S4 240 VAC Normally Closed Conduit Connector S5 12 VDC Normally Open Conduit Connector S6 24 VDC Normally Open Conduit Connector S7 1...

Page 13: ...s T01 Closed Center 240 VAC Hirschmann w out Plugs K01 Closed Center 12 VDC Hirschmann w out Plugs J01 Closed Center 24 VDC Hirschmann w out Plugs Y02 Open Center 120 VAC Hirschmann w out Plugs T02 Op...

Page 14: ...posite reservoirs it is recommended to remove the filler cap and use a siphon to remove the oil Dispose of or recycle the used fluid according to local regulations Once the fluid is removed an examina...

Page 15: ...ower Recommendations at Flow Pressure Pump Size Nominal GPM Pressure Bar PSI 1725 3450 34 500 69 1000 103 1500 138 2000 172 2500 207 3000 04 50 HP 50 HP 50 HP 50 HP 50 HP 50 HP 04 50 HP 50 HP 50 HP 75...

Page 16: ...not return promptly to the neutral position the pump flow will be dumping continuously This builds up heat rapidly If a relief valve is set too low part of the oil will be dumped across the valve wit...

Page 17: ...lation instructions Will not build pressure Reservoir does not have enough fluid Fill the reservoir per the Installation instructions with an approved fluid Motor rotation is not clockwise from fan en...

Page 18: ...currently Only one solenoid can be energized at any given time to prevent coil burnout Ensure voltage signals are interlocked to prevent this condition Mechanical damage to leads Replace all damaged w...

Page 19: ...ted either electronically or by post Description Oildyne 550 Series Power Units Model Number As Applies Sizes All Serial Number All The following standards have either been referred to or complied wit...

Page 20: ...7272 505 800 parker easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands...

Reviews: