13

Bulletin HY22-3220A/US

Instruction Manual

550 Series Hydraulic Power Units

4-WAY VALVE (ALL D03 SIZE)

CODE DESCRIPTION (For use only with Circuit Codes D0 and D1)

NNN

No 4-Way Valve Included

01Y

Closed Center, 120 VAC, Conduit Connectors

01T

Closed Center, 240 VAC, Conduit Connectors

01K

Closed Center, 12 VDC, Conduit Connectors

01J

Closed Center, 24 VDC, Conduit Connectors

02Y

Open Center, 120 VAC, Conduit Connectors

02T

Open Center, 240 VAC, Conduit Connectors

02K

Open Center, 12 VDC, Conduit Connectors

02J

Open Center, 24 VDC, Conduit Connectors

07Y

Float Center, 120 VAC, Conduit Connectors

07T

Float Center, 240 VAC, Conduit Connectors

07K

Float Center, 12 VDC, Conduit Connectors

07J

Float Center, 24 VDC, Conduit Connectors

08Y

Tandem Center, 120 VAC, Conduit Connectors

08T

Tandem Center, 240 VAC, Conduit Connectors

08K

Tandem Center, 12 VDC, Conduit Connectors

08J

Tandem Center, 24 VDC, Conduit Connectors

30Y

Single Solenoid, 120 VAC, Conduit Connector

30T

Single Solenoid, 240 VAC, Conduit Connector

30K

Single Solenoid, 12 VDC, Conduit Connector

30J

Single Solenoid, 24 VDC, Conduit Connector

Y01

Closed Center, 120 VAC, Hirschmann w/out Plugs

T01

Closed Center, 240 VAC, Hirschmann w/out Plugs

K01

Closed Center, 12 VDC, Hirschmann w/out Plugs

J01

Closed Center, 24 VDC, Hirschmann w/out Plugs

Y02

Open Center, 120 VAC, Hirschmann w/out Plugs

T02

Open Center, 240 VAC, Hirschmann w/out Plugs

K02

Open Center, 12 VDC, Hirschmann w/out Plugs

J02

Open Center, 24 VDC, Hirschmann w/out Plugs

Y07

Float Center, 120 VAC, Hirschmann w/out Plugs

T07

Float Center, 240 VAC, Hirschmann w/out Plugs

K07

Float Center, 12 VDC, Hirschmann w/out Plugs

J07

Float Center, 24 VDC, Hirschmann w/out Plugs

Y08

Tandem Center, 120 VAC, Hirschmann w/out Plugs

T08

Tandem Center, 240 VAC, Hirschmann w/out Plugs

K08

Tandem Center, 12 VDC, Hirschmann w/out Plugs

J08

Tandem Center, 24 VDC, Hirschmann w/out Plugs

Y30

Single Solenoid, 120 VAC, Hirschmann w/out Plug

T30

Single Solenoid, 240 VAC, Hirschmann w/out Plug

K30

Single Solenoid, 12 VDC, Hirschmann w/out Plug

J30

Single Solenoid, 24 VDC, Hirschmann w/out Plug

550

MOTOR SELECTION - TEFC

Single Phase = 115/230 VAC, 60 HZ

Three Phase = 230/460 VAC, 60 HZ

CODE

HP

RPM

PHASE

  TC

.50

1725

Single

  TD

.50

1725

Three

  TM

.50

3450

Single

  TT

.50

3450

Three

  TE

.75

1725

Single

  TF

.75

1725

Three

  TN

.75

3450

Single

  TU

.75

3450

Three

  TJ

1.0

1725

Single

  TK

1.0

1725

Three

  TP

1.0

3450

Single

  TW

1.0

3450

Three

  TL

1.5

1725

Single

  TO

1.5

1725

Three

  TQ

1.5

3450

Single

  TX

1.5

3450

Three

  TV

2.0

1725

Single

  TR

2.0

1725

Three

  TS

2.0

3450

Single

  TY

2.0

3450

Three

PUMP SIZE

CODE DISPLACEMENT

   

04

.04 CIPR

   

07

.07 CIPR

   

10

.10 CIPR

   

14

.14 CIPR

   

17

.17 CIPR

   

20

.20 CIPR

RESERVOIR

CODE     VOLUME

   

05

0.5 Gal. Steel

   

10

1.0 Gal. Steel

   

15

1.5 Gal. Steel

   

50

5.0 Gal. Steel

   

06

0.5 Gal. Plastic

   

11

1.0 Gal. Plastic

   

16

1.5 Gal. Plastic

   

26

2.5 Gal. Plastic

CIRCUIT

CODE DESCRIPTION

  D0

D03 Pad & Extension Fittings

  D1

D03 Pad with Dual PO Check Manifold (Manapak)

(for use with D03 Directional Control Valves)

  SA

Standard Pressure & Tank Ports

  SW

Std P & T Ports with Outlet Port Check Valve

Two Position Two Way Cartridge Valves

Following circuits include outlet port check valve:

  S1

12 VDC, Normally Closed, Conduit Connector

  S2

24 VDC, Normally Closed, Conduit Connector

  S3

120 VAC, Normally Closed, Conduit Connector

  S4

240 VAC, Normally Closed, Conduit Connector

  S5

12 VDC, Normally Open, Conduit Connector

  S6

24 VDC, Normally Open, Conduit Connector

  S7

120 VAC, Normally Open, Conduit Connector

  S8

240 VAC, Normally Open, Conduit Connector

  P1

12 VDC, Normally Closed, DIN Connector

  P2

24 VDC, Normally Closed, DIN Connector

  P3

120 VAC, Normally Closed, DIN Connector

  P4

240 VAC, Normally Closed, DIN Connector

  P5

12 VDC, Normally Open, DIN Connector

  P6

24 VDC, Normally Open, DIN Connector

  P7

120 VAC, Normally Open, DIN Connector

  P8

240 VAC, Normally Open, DIN Connector

FLOW CONTROL

(for use with Cartridge Valves)

CODE DESCRIPTION

  NN

None (use with D0 and D1 circuits)

  HP

None (use with all other circuits)

  F1

Pressure Compensated, 2 to 4 LPM (.5 to 1.0 GPM)

  F2

Pressure Compensated, 4 to 8 LPM (1.0 to 2.0 GPM)

RV SETTING

In multiples of 100 psi

Examples

04 = 400 psi

12 = 1200 psi

29 = 2900 psi

550 POWER UNIT
- includes relief
  valve

Note: 5 gal. steel reservoir 

can be mounted vertically 

only. All others are vertical 

and horizontal ready

(100 psi = 6.8 bar)

 NN

None Customer Supplied

“No Motor” note:
A 56C adapter kit is
available enabling the 
customer to provide and
mount a standard 56C
with base electric motor.

Standard Product Model Code

Parker Hannifin 

HPS Division 

New Hope, MN 55428 USA

Summary of Contents for Oildyne 550 Series

Page 1: ...Oildyne 550 Series Hydraulic Power Units Bulletin HY22 3220A US Instruction Manual Effective August 01 2011 416181...

Page 2: ...sible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems Offer of Sale Please contact your...

Page 3: ...se see pages 7 and 8 The life expectancy of Parker Oildyne power units is directly tied to the frequency of use the product in which it is incorporated and the application Shipping weights for the 550...

Page 4: ...11 80 88 9 3 50 87 4 3 44 171 5 6 75 135 1 5 32 SINGLE PHASE ONLY FILLER BREATHER 101 6 169 1 4 00 6 50 65 0 2 56 182 1 MAX 7 17 165 1 6 50 76 2 3 00 62 0 2 44 62 0 2 44 4X 8 6 34 SLOT 4 LITER 5 6 LIT...

Page 5: ...TR THD O RING PORTS P T 304 8 12 00 1 GAL 4 LITER 406 4 16 00 1 1 2 GAL 5 6 LITER 101 3 3 99 24 1 0 95 140 4 5 53 MOTOR HEIGHT 237 2 299 7 9 34 11 80 SINGLE PHASE ONLY FILLER BREATHER RELIEF VALVE RET...

Page 6: ...10 00 304 8 12 00 25 8 1 02 171 5 6 75 598 8 23 58 311 3 12 26 51 3 2 02 131 8 5 19 63 6 2 51 58 6 2 31 231 6 9 12 66 8 2 63 82 6 3 25 39 9 1 57 93 5 3 68 215 9 8 50 181 7 13 GAUGE PORT LOCATION SAE 6...

Page 7: ...Instruction Manual 550 Series Hydraulic Power Units Power Unit Schematics Hydraulic Schematics P T P T P T P T SA CIRCUIT SW CIRCUIT S1 S4 P1 P4 CIRCUITS S5 S8 P5 P8 CIRCUITS Parker Hannifin HPS Divis...

Page 8: ...NSATED FLOW CONTROL F1 OR F2 S5 S8 P5 P8 CIRCUITS WITH PRESSURE COMPENSATED FLOW CONTROL F1 OR F2 D0 CIRCUIT D03 VALVE TO BE SELECTED D1 CIRCUIT INCLUDES MANAPAK DUAL P0 CHECK VALVE D03 VALVE TO BE SE...

Page 9: ...s Power Units are complete assemblies A small portion is created without the electric motors allowing the customer to purchase and install alternate motors There is a C face kit available Oildyne part...

Page 10: ...most mineral based hydraulic fluids with viscosities between 32 cSt 150 SSU and 64 cSt 300 SSU at 38 C 100 F For fluids other than these please contact Oildyne Division with the details If users wish...

Page 11: ...ted emissions should be performed in accordance with the Electromagnetic Compatibility EMC Generic Emissions standards for environments appropriate to the end use product to confirm compliance with th...

Page 12: ...sed Conduit Connector S3 120 VAC Normally Closed Conduit Connector S4 240 VAC Normally Closed Conduit Connector S5 12 VDC Normally Open Conduit Connector S6 24 VDC Normally Open Conduit Connector S7 1...

Page 13: ...s T01 Closed Center 240 VAC Hirschmann w out Plugs K01 Closed Center 12 VDC Hirschmann w out Plugs J01 Closed Center 24 VDC Hirschmann w out Plugs Y02 Open Center 120 VAC Hirschmann w out Plugs T02 Op...

Page 14: ...posite reservoirs it is recommended to remove the filler cap and use a siphon to remove the oil Dispose of or recycle the used fluid according to local regulations Once the fluid is removed an examina...

Page 15: ...ower Recommendations at Flow Pressure Pump Size Nominal GPM Pressure Bar PSI 1725 3450 34 500 69 1000 103 1500 138 2000 172 2500 207 3000 04 50 HP 50 HP 50 HP 50 HP 50 HP 50 HP 04 50 HP 50 HP 50 HP 75...

Page 16: ...not return promptly to the neutral position the pump flow will be dumping continuously This builds up heat rapidly If a relief valve is set too low part of the oil will be dumped across the valve wit...

Page 17: ...lation instructions Will not build pressure Reservoir does not have enough fluid Fill the reservoir per the Installation instructions with an approved fluid Motor rotation is not clockwise from fan en...

Page 18: ...currently Only one solenoid can be energized at any given time to prevent coil burnout Ensure voltage signals are interlocked to prevent this condition Mechanical damage to leads Replace all damaged w...

Page 19: ...ted either electronically or by post Description Oildyne 550 Series Power Units Model Number As Applies Sizes All Serial Number All The following standards have either been referred to or complied wit...

Page 20: ...7272 505 800 parker easteurope parker com LV Latvia Riga Tel 371 6 745 2601 parker latvia parker com MX Mexico Apodaca Tel 52 81 8156 6000 MY Malaysia Shah Alam Tel 60 3 7849 0800 NL The Netherlands...

Reviews: