14(26)
Hydraulic Oil Filter
EAPF 1
Operation and Maintenance Instructions
72.09.195.66 rev.B
Parker Hannifin Manufacturing Netherlands (Filtration) B.V.
9. MAINTENANCE OF THE SYSTEM
Always use proper tools and lifting devices with sufficient capacity.
Replace damaged or defective equipment or lifting devices without delay
There is hot fluid inside the device, and the outer surfaces of the device
also become hot. Do not touch the device or attempt to open the filter
without proper protection.
Do not change any settings of the system unless instructions are
provided in the manual or without authorization from the manufacturer.
Never exceed any of the pressure values given by the manufacturer.
All parts replaced in relation with maintenance or repairs shall be original
spare parts.
Remember the following notes and warnings concerning pressurized
fluids:
•
Components and hoses contain high-pressure oil
•
High-pressure oil sprays can penetrate the skin and cause severe internal damage. In
case of an accident, contact medical support without delay.
•
Oil is hot and will cause burns on the skin.
•
High-pressure oil leaks are not necessarily visible. Do not examine the system for leaks
with bare hands, use a piece of cardboard or other equivalent material.
•
Before any connections are opened, the system must be relieved of pressure.
•
Clean all connections and components in conjunction with maintenance work.
•
Check all connections for tightness.