13
5 Servicing
The recommended service procedures identified below, along with all other repair and calibration work, should be undertaken by a Parker
Hannifin approved engineer.
5.1 Cleaning
Clean the equipment with a damp cloth only and avoid excessive moisture around any electrical sockets. If required you may use a mild
detergent, however do not use abrasives or solvents as they may damage the warning labels on the equipment.
5.1.1 Service Intervals
Key:
Component
Operation
Daily
W
e
ekl
y
12
Months
(80
00
Hrs.)
36
Months
(2400
0Hrs.
)
Generator
Check that the Power On indicator is illuminated and cycles from
red to green.
Generator
Check the drain valve is discharging on a regular basis.
Generator
Check for leaks
Generator
Check the pressure gauges during operation
Generator
Check that there is ventilation clearance around the generator.
Generator
Check the condition of electrical supply cables and conduits.
Generator
Recommended Service A
Replace the filters
Generator
Recommended Service B
Replace the compressor (Option 1 only)
Generator
Recommended Service C
Replace the valves
Service
12 Months
(800
0 H
rs.
)
24 Months
(1
6000
Hrs.
)
36 Months
(2
4000
Hrs.
)
48 Months
(3
2000
Hrs.
)
60 Months
(4
0000
Hrs.
)
72 Months
(4
8000
Hrs.
)
84 Months
(5
6000
Hrs.
)
96 Months
(6
4000
Hrs.
)
1
08 Mo
nths
(7
2000
Hrs.
)
1
20 Mo
nths
(8
0000
Hrs.
)
A
B
C
Check
Essential Procedure
servicereminder.com
Servicereminder.com is a web based reminder service developed to track when service work is due to be carried out. This ensures that parts can be ordered in
advance and that the service is carried out at the optimum time in accordance with the manufacturers recommendations. This service is free to use, simply log on
to
www.servicereminder.com
and select New User Registration.