17
VAC-SIF-05
Training & Maintenance Manual
CVX0260B
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
The Discrete units provide M12 or M18 connectors for ease of
installation. The circuit includes the Air Economizing Function
and PNP (Sourcing) Outputs.
No external PLC programming
is required for Air Economizing Functions because this func-
tion is built into the electrical unit.
The following are the Pin
Outs for these Discrete units.
A
CH2 Blow Off
B
CH2 Sensor Power
C
CH2 Part Presence
D
CH2 VAC Control
E
CH1 Blow Off
F
CH1 Sensor Power
G
CH1 Part Presence
H
CH1 VAC Control
J
DC Voltage Monitor
K
Common
L
Ground
M Not Used
N
Not Used
P
Output Power
R
Not Used
S
Not Used
T
Not Used
U
Not Used
24VDC
J
K
M
N
B
H
S
R
D
E
G
F
L
A
T
U
P
C
Face View - Male 18-Pin Connector
Notes:
Pin B & F are jumpered inside unit.
Either pin can connect power to both sensors.
Pin P & J are jumpered inside unit.
This is for monitoring power only. Pin P is not necessary
for operation of the unit.
2
4
3
Output
Channel 1
1
2
4
5
3
Input
Sensors
2
4
3
Output
Channel 2
2
4
3
Aux. Power
1
1
1
1
Power (Brown)
2
CH2 Part Presence (White)
3
Common (Blue)
4
CH1 Part Presence (Black)
5
Not Used (Gray)
1
Not Used (Brown)
2
Out CH2 Blow Off (White)
3
Common (Blue)
4
Out CH2 VAC (Black)
1
Not Used (Brown)
2
Out CH1 Blow Off (White)
3
Common (Blue)
4
Out CH1 VAC (Black)
1
Not Used (Brown)
2
Not Used (White)
3
Auxilary Power Common (Blue)
4
Power (Black)
M12, 24VDC
Output - 4-Pin, M12, Keyed Male
Input - 5-Pin, M12, Keyed Male
Aux. Power - 4-Pin, M12, Keyed Male
M18, 24VDC
18-Pin Connector
Discrete Units