Parker CVX0260B Training & Maintenance Manual Download Page 18

18

VAC-SIF-05

Training & Maintenance Manual

CVX0260B

Parker Hannifin Corporation

Pneumatic Division

Richland, Michigan

www.parker.com/pneumatic

warnings

      wARNING

To  avoid  unpredictable  system  behavior  that  can  cause  personal 

injury and property damage:

•  Disconnect electrical supply (when necessary) before installation, 

servicing, or conversion.

•  Disconnect air supply and depressurize all air lines connected to 

this product before installation, servicing, or conversion.

•  Operate within the manufacturer’s specified pressure, temperature, 

and other conditions listed in these instructions.

•  Medium  must  be  moisture-free  if  ambient  temperature  is  below 

freezing.

•  Service according to procedures listed in these instructions.
•  Installation,  service,  and  conversion  of  these  products  must  be 

performed  by  knowledgeable  personnel  who  understand  how   

pneumatic products are to be applied.

•  After  installation,  servicing,  or  conversion,  air  and  electrical 

supplies (when necessary) should be connected and the product 

tested  for  proper  function  and  leakage.  If  audible  leakage  is 

present, or the product does not operate properly, do not put into 

use.

•  warnings  and  specifications  on  the  product  should  not  be 

covered by paint, etc. If masking is not possible, contact your local 

representative for replacement labels.

      wARNING

FAIlURE  OR  IMPROPER  SElECTION  OR  IMPROPER  USE  OF 

THE  PRODUCTS  AND/OR  SYSTEMS  DESCRIBED  HEREIN  OR 

RElATED ITEMS CAN CAUSE DEATH, PERSONAl INJURY AND 

PROPERTY DAMAGE.

This document and other information from Parker Hannifin Corporation, 

its  subsidiaries  and  authorized  distributors  provide  product  and/or 

system  options  for  further  investigation  by  users  having  technical 

expertise.  It  is  important  that  you  analyze  all  aspects  of  your 

application,  including  consequences  of  any  failure  and  review  the 

information concerning the product or systems in the current product 

catalog. Due to the variety of operating conditions and applications 

for  these  products  or  systems,  the  user,  through  its  own  analysis 

and testing, is solely responsible for making the final selection of the 

products and systems and assuring that all performance, safety and 

warning requirements of the application are met.
The products described herein, including without limitation, product 

features, specifications, designs, availability and pricing, are subject 

to change by Parker Hannifin Corporation and its subsidiaries at any 

time without notice.

EXTRA  COPIES  OF THESE  INSTRUCTIONS  ARE  AVAIlABlE  FOR 

INClUSION IN EQUIPMENT / MAINTENANCE MANUAlS THAT UTIlIZE 

THESE PRODUCTS. CONTACT YOUR lOCAl REPRESENTATIVE.

!

!

Summary of Contents for CVX0260B

Page 1: ...Pneumatic Division Richland Michigan 49083 Training Maintenance Manual for CVX0260B Vacuum Generators VAC SIF 05 Training Maintenance Manual CVX0260B ISSUED July 2013 Supersedes November 2012...

Page 2: ...pilot valve blow off needle control valve pressure sensor vacuum check valve vacuum filter and exhaust filter Each Vacuum Generator is mounted to a 2 Station bar manifold with an optional electrical...

Page 3: ...level within the system The vacuum operated pilot valve is turned back on at a vacuum level n_2 The hysteresis feature of the vacuum sensor can maintain the vacuum level of the system indefinitely wh...

Page 4: ...tput 1 to Activate Vacuum VAC ON Vacuum Begins Vacuum Mode Continues Part Presence Command VAC ON Sensor Output 1 N C Preset n_1 18 inHg Sensor Output 2 N O Preset P_3 10 inHg n_1 n_2 P_3 P_4 Robot Co...

Page 5: ...e IDLE state Restore Power When the output power is restored with input and output power the unit will return to the output status of the PLC PC program Factory Sensor Settings All factory settings ca...

Page 6: ...Individual Vacuum Channels 3 8 G Ports or 3 8 NPT OperatingTemperature 32 to 122 F 0 to 50 C Operating Pressure 70 PSI Vacuum Filtration 130 m Noise Level 72dB Air Consumption 10 41 SCFM Maximum Vacuu...

Page 7: ...Not Shown 14 PSCVXDNB DeviceNet PSCVXD3B M12 Discrete PSCVXN3B 18 Pin Discrete 15 MPS V23C NC NPN Sensor PSCVXDNB PSCVXD3B PSCVXN3B Contents The CVX0260B is supplied with four 4 M5 x 1 Socket Head Cap...

Page 8: ...ach CVX0260B incorporates a small filter housed on the body to protect the internal components of the generator Additional maintenance of this filter will also vary with each environment and applicati...

Page 9: ...PC Program Sensor Output 1 ou1 to N O Manually changing sensor OU1 from N C to N O LED should change state See Sensor Verify Sensor Output 1 settings Programming for changing Output status Verify tha...

Page 10: ...cuum confirmation High Signal to the PLC PC at set point P_3 prior to part on Log Part On and Part Off Vacuum Check Exhaust and Vacuum Filters for Pressure P_3 must be between Part Off obstructions to...

Page 11: ...ify H 1 is illuminated at 0 inhg ou1 N C N O no signal will be passed through the Air Economizing Setting Sensor Output 1 must be set to sensor to activate the vacuum pilot from the Normally Closed Pa...

Page 12: ...p Vacuum CVX0260BE0SDN Dimensions 2 56 65 0 3 51 89 2 4 31 109 5 1 76 44 6 2 24 57 0 1 97 50 0 Blow Off Valve Mounting Holes 4 5 5mm Blow Off Needle Adjustment Vacuum Valve Vacuum Filter Housing 67 17...

Page 13: ...try and the two sensors The auxiliary power bus pro vides power for the vacuum solenoids and blow off solenoids No external PLC programming is required for Air Economizing Functions because this funct...

Page 14: ...Bit Strobed and Polled messaging General Description The Convum Vacuum Generator operates as a Group II Only slave on the DeviceNet network The unit supports the following types of messaging Explicit...

Page 15: ...as the Poll response Sensor 1 Dip Switches VAC1 BL01 BL02 VAC1 Sensor 2 1 2 3 4 5 6 7 8 Sensor 1 VAC2 BL02 BL01 VAC1 Sensor 2 O N 1 2 3 4 5 6 7 8 O N Network Status Module Status Factory DIP Switch Se...

Page 16: ...XN3B M18 24VDC Optional Mounting Plate 13 00 330 2 3 50 101 6 12 18 309 4 2 00 50 8 50 12 7 1 00 25 4 28 7 13 Dia Thru Typ 4 Places 27 6 85 Typ 4 Places 438 11 13 Dia Typ 4 Places 2 56 65 0 3 51 89 2...

Page 17: ...put Power R Not Used S Not Used T Not Used U Not Used 24VDC J K M N B H S R D E G F L A T U P C Face View Male 18 Pin Connector Notes Pin B F are jumpered inside unit Either pin can connect power to b...

Page 18: ...red by paint etc If masking is not possible contact your local representative for replacement labels WARNING FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND OR SYSTEMS DESCRIBED HERE...

Page 19: ...tore Final Key returns sensor to current pressure reading 2 1 Troubleshooting Verify ou1 is set NC LED 1 will be ON if NC Check DIN LED for electrical connection Use Manual Overrides to confirm manual...

Page 20: ...change to store Press Up or to change to store Final Key returns sensor to current pressure reading 2 1 Troubleshooting Verify ou1 is set NC LED 1 will be ON if NC Check DIN LED for electrical connect...

Page 21: ...x 1x 1x Press button for more than 3 seconds NO Mode 2 5ms Lock Mode Measure mode Key lock mode can prevent operation mistakes Press button for less than 5 seconds Key lock unlock mode Use the or butt...

Page 22: ...and then restart If error condition remains please return to factory for inspection Er6 Internal system error Er7 Internal data error Output type Manual setting mode Auto setting mode Do not use on C...

Page 23: ...y any customer Buyer shall be governed by all of the following Terms and Conditions Buyer s order for any item described in its document when communicated to Seller verbally or in writing shall consti...

Page 24: ...21 4PDN Option 2 E mail pdnapps parker com Customer Support Phone 877 321 4PDN Option 1 E mail pdncustsvc parker com Web site www parker com pneumatics Parker Hannifin Corporation Pneumatic Division 8...

Reviews: