6
VAC-SIF-05
Training & Maintenance Manual
CVX0260B
Parker Hannifin Corporation
Pneumatic Division
Richland, Michigan
www.parker.com/pneumatic
Blow-Off
Adjustment Screw
Blow-Off
Pilot Valve
Vacuum
Pilot Valve
Blow-off Adjustment
The volume of air during the blow-off function to release the
workpiece can be set by turning the needle adjustment up
or down. Access the needle adjustment through opening of
protective cover (topside).
Units of Measure
The pressure sensor has an LED function that indicates
the degree of pressure in the system. The units can be
changed, but are factory set to inHg (inches of Mercury).
The relationship of inHg with a gauge pressure scale and
absolute pressure scare are in the following table. In general,
the negative sign on the gauge pressure scale is assumed
and may or may not be noted on documentation.
Negative Gauge
Absolute
Pressure
Pressure
Inches of Mercury
PSIG
PSIA
inHg
0
14.7
0
Atmospheric Pressure at Sea level
-1.5
13.2
3
-3.0
11.7
6
-4.5
10.2
9
Typical Porous Vacuum level
-6.0
8.7
12
-7.5
7.2
15
-9.0
5.7
18
-10.5
4.2
21
Typical Non-Porous Vacuum level
-12.0
2.7
24
-13.5
1.2
27
-14.7
0
29.92
Perfect Vacuum (Zero Reference Pressure)
Basic Vacuum Pressure Measurements Units
Specifications
Specifications
CVX0260B Specifications
Media
Non-lubricated Dry Air
Pressure Port
3/8" G, 3/8" NPT Through Port
Vacuum Ports
2 Individual Vacuum Channels
3/8" G Ports or 3/8" NPT
Operating Temperature
32° to 122°F (0° to 50°C)
Operating Pressure
70 PSI
Vacuum Filtration
130 µm
Noise level
72dB
Air Consumption
10.41 SCFM
Maximum Vacuum level
-25.0 inHg
Control Valve Specifications
3-way
Pilot Valves
Manual Operation
Manual Overrides Available
Electrical Connector
DIN type w/LED and Diode
Protection, IP65 Rating
Power Supply
24VDC ± 10%
Power Consumption
1.2W
Pressure
70 PSI
Sensor Specifications
Media
Non-lubricated Dry Air
Operating Temperature
32° to 122°F (0° to 50°C)
Humidity
40 to 85% R.H.
Electrical Connection
4-Pin, M8 Connector
Power Supply
10.8 to 30 VDC,
Ripple Vp-p 10% Max.
Diode Protection
Display
3-Digit, 7-Segment LED
Units of Measure
inHg, mmHg, bar, kPa,
Selectable
Display Resolution
0.1 kPa, 0.001 bar, 1 mmHg,
0.1 inHg Selectable
2-Switch Outputs
Individually Selectable N.O or
N.C., 80mA, 30V with
Overcurrent Protection,
LED Status
Operating Mode
Hysteresis Adjustable
Response Time
2ms
Repeatability
± 0.2% F.S.
General Protection
CE Rated
Current Consumption
<55mA
Emergency Stop Operating System Specifications
Two-way Valve
Diaphragm Actuated,
Pneumatic Output
Media
Non-lubricated Air, Dry Air
Operating Range
-4.5 to -25 inHg Vacuum
Pressure Operating Range
70 PSI
Accuracy
± 1.5 inHg
Port Connection
M5 Female
Air Supply
Normally Closed
Emergency Stop Electrical Valve Specifications
3-way Valve
Direct Acting
Media
Air
Operating Range
70 PSI
Electrical Connection
DIN Connector w/LED and
Diode Protection, IP65
Operating Voltage
24VDC ± 10%
Power Consumption
1.8W
Current
0.075A