Mount the CM2115 in an environment that is within its ambient temperature
range of –40 °C to +85 °C.
2.
Mount the CM2115 in an environment that is within its particle ingress rating.
The sealing standard for the CM2115 is EP455 level 1.
Note:
The CM2115 has not been tested for water ingress according to the
EP455 level 1 standard.
The CM2115 is protected from aggressive pressure wash up to 1000 psi at 1 m
(3.28 ft.).
Warning! Damage to equipment.
Exercise caution when pressure-
washing the CM2115. The severity of a pressure wash can exceed the
CM2115 pressure wash specifications related to water pressure, water
flow, nozzle characteristics, and distance. Under certain conditions a
pressure wash jet can cut wires.
10.1.3. Mounting the CM2115
Secure the CM2115 to the vehicle using four 1/4"-20 or M6 fasteners.
10.1.3.1. Recommended Mounting Orientation
The CM2115 should be mounted so that moisture drains away from it.
Figure 24: Recommended orientations