![Parker CM2115 User Manual Download Page 43](http://html1.mh-extra.com/html/parker/cm2115/cm2115_user-manual_3889688043.webp)
User Guide
33
Outputs
6.1.3. 5 A High-Side Output with Current Sense
Capabilities
These outputs provide 5 A maximum continuous current with accurate current
sensing. The current sensing provides accurate readings to detect single load
disconnect on parallel driven load applications (i.e. when multiple loads are
driven by a single output).
The following table provides specifications for the CM2115's 5 A high-side
outputs:
5 A High-Side Output with Current Sense Specifications
Item
MIN
NOM
MAX
UNIT
Switchable voltage range
6
-
32
V
Output current
0
-
5
A
Output on state resistance
-
20
-
m
Ω
Overvoltage -
-
36
V
PWM frequency
-
-
500
Hz
PWM resolution
-
0.1
-
%
Integrated flyback diode
-
No
-
-
Inductive pulse protection
-
-
628
V (peak)
Digital feedback negative going threshold
-
-
2.69
V
Digital feedback positive going threshold
2.86
-
-
V
Open load detection resistance
9.9k
10k
10.1k
Ω
Current Sense resistance
24.75
25
25.25
m
Ω
Current Sense gain
-
275
-
mV/A
Current Sense resolution
-
-
4.4
mA
Current Sense accuracy - Full Scale (5 A)
-
3
-
%
Leakage current when off
-
-
15
uA
Fixed Output Protection
The outputs have the following fixed protection mechanisms: