Parker Hannifin Corporation • 

Refrigerating Specialties Division

2445 South 25th Avenue • Broadview, IL 60155-3891
Telephone: (708) 681-6300 • Fax (708) 681-6306

VALVE

À

  FPT  FLANGES

                          WELDING FLANGES

Ã

 FLANGES

SIZE

Nominal

Sock Weld

Weld Neck

Flange Package

Tubing

Fitting

Nom.

Flange

Pipe Size

Socket I.D.

Neck O.D.

Number(2/Pkg)

O.D.

I.D.

Flge Pkg.

Pipe Size

Pkg. No.

Á

Socket

Weld

Â

No. (2/Pkg)

mm

Inches

Inches

(2/Pkg) Inches NW No. Inches

mm

Inches

mm

Weld

Neck

Inches

mm

Inches

mm

20

3/4

3/4

200016

3/4

20

1.070

27.81

1.050

26.67 200020

200023

1-1/8

28.57

1.130

28.70

200027

and

and

1

200017

1

25

1.365

34.67

1.315

33.40 200021

200024

1-3/8

34.92

1.380

33.05

200028

25

1

1-1/4

200018

1-1/4

32

1.705

43.31

1.660

42.16 200022

200025

1-5/8

41.27

1.631

41.43

200029

1-1/4

200030

1-1/4

32

1.705

43.31

1.660

42.16 200032

200034

1-3/8

34.92

1.380

35.05

200036

32

1-1/4

1-1/2

200031

1-1/2

40

1.930

49.02

1.900

48.26 200033

200035

1-5/8

41.27

1.631

41.43

200037

2-1/8

53.97

2.131

54.13

200038

40

1-5/8

1-1/2

200039

1-1/2

40

1.930

49.02

1.900

48.26 200041

200043

1-5/8

41.27

1.631

41.43

200045

and

and

2

200040

2

50

2.445

62.10

2.375

60.33 200042

200044

2-1/8

53.97

2.131

54.13

200046

50

2

2-5/8

66.67

2.631

66.83

200047

65

2-1/2

2-1/2

200048

2-1/2

65

2.945

2.875

73.03 200049

200050

2-5/8

66.67

2.631

66.83

200051

3-1/8

79.37

3.131

79.53

200052

75

3

3

200053

3

80

3.575

90.81

3.500

88.90 200054

200055

3-1/8

79.37

3.131

79.53

200056

3-5/8

92.07

3.631

92.23

200057

100

4

4

200062

4

100

4.575 116.20

4.500 114.30 200063

200064

4-1/8

104.77

4.132

104.95

200065

À

  

FPT: Internal NPT (USA Standard Taper Pipe Thread).

Á

NW: Metric equivalent nominal size for steel tubing.

Â

Metric copper tubing used for refrigeration.

Ã

ODS connections to fit copper tubing of given outside
d

iameter. (Not for use with ammonia)

Definitions:

ODS - Outside Diameter Sweat
I.D. - Inside Diameter
O.D. - Outside Diameter
N.A. - Not Available

Flange Bolt Torque Requirements

Bolt Diameter

Valve Port Size

Torque

11mm (7/16")

13mm (1/2 ")

3.9 mkg (28 ft lb)

16mm (5/8")

20-50mm (3/4 "- 2")

11.8 mkg (85 ft lb)

19mm (3/4")

65-75mm (2-1/2 "- 3")

14.5 mkg (105 ft lb)

22mm (7/8")

100mm (4")

22.1 mkg (150 ft lb)

Safe Operation (See also Bulletin RSBCV)

People doing any work on a refrigeration system must be qualified
and completely familiar with the system and the Refrigerating
Specialties Division valves involved, or all other precautions will be
meaningless. This includes reading and understanding pertinent
Refrigerating Specialties Division product Bulletins, and Safety Bulletin
RSB prior to installation or servicing work.

Where cold refrigerant liquid lines are used, it is necessary that certain
precautions be taken to avoid damage which could result from liquid
expansion. Temperature increase in a piping section full of solid liquid
will cause high pressure due to the expanding liquid which can possibly
rupture a gasket, pipe or valve. All hand valves isolating such sections
should be marked, warning against accidental closing, and must not
be closed until the liquid is removed. Check valves must never be
installed upstream of solenoid valves, or regulators with electric shutoff,
nor should hand valves upstream of solenoid valves or downstream
of check valves be closed until the liquid has been removed. It is
advisable to properly install relief devices in any section where liquid
expansion could take place.

Avoid all piping or control arrangements which might produce thermal
or pressure shock.

For the protection of people and products, all refrigerant must be
removed from the section to be worked on before a valve, strainer, or
other device is opened or removed.

Flanges with ODS connections are not suitable for ammonia service.

Warranty

All Refrigerating Specialties Products are warranted against defect in
workmanship and materials for a period of one year from date of
shipment from factory. This warranty is in force only when products
are properly installed, field assembled, maintained and operated in
use and service as specifically stated in Refrigerating Specialties
Catalogs or Bulletins for normal refrigeration applications, unless
otherwise approved in writing by Refrigerating Specialties Division.
Defective products, or parts thereof, returned to the factory with
transportation charges prepaid and found to be defective by factory
inspection will be replaced or repaired at Refrigerating Specialties’
option, free of charge, F.O.B. factory. Warranty does not cover products
which have been altered or repaired in the field; damaged in transit,
or have suffered accidents, misuse, or abuse. Products disabled by
dirt, or other foreign substances will not be considered defective.

THE EXPRESS WARRANTY SET FORTH ABOVE CONSTITUTES
THE ONLY WARRANTY APPLICABLE TO REFRIGERATING
SPECIALTIES PRODUCTS, AND IS IN LIEU OF ALL OTHER
WARRANTIES, EXPRESSED OR IMPLIED, WRITTEN OR ORAL,
INCLUDING ANY WARRANTY OR MERCHANTABILITY, OR
FITNESS FOR A PARTICULAR PURPOSE. No employee, agent,
dealer or other person is authorized to give any warranties on behalf
of Refrigerating Specialties, nor to assume, for Refrigerating
Specialties, any other liability in connection with any of its products.

FLANGES

Summary of Contents for ADAPTOMODE A4AS

Page 1: ...e A4 Series of Regulators is 45 C to 105 C 50 F to 220 F Principles of Operation See Fig 1 The inlet pressure enters the space under the diaphragm through passage N When the force created by the pressure exceeds the force of the range spring the diaphragm is lifted off the pilot seat allowing pressure to enter on top of the power piston This causes the power piston to move downward forcing the mod...

Page 2: ... open thereby bypassing the regulator function i e not regulating However in the wide open mode the regulator will still require the 0 14 bar 2 psi minimum pressure drop When the solenoid is de energized the valve functions as an Inlet Pressure Regulator Purpose The Type A4AB frequently is used with the wide open function where maximum refrigeration capacity from an evaporator is required During t...

Page 3: ...Refrigerating Specialties Division 3 Fig 3 A4AS Fig 4 A4AB Fig 5 A4AD Fig 2 A4AZ ...

Page 4: ...lts to stretch or align pipe Even the heavy duty semisteel body of an A4A can be distorted causing the precision parts to bind The regulator should be installed in a location where it is easily accessible for adjustment and maintenance The location should be such that the regulator can not be easily damaged by material handling equipment When it is necessary to insulate the regulator and companion...

Page 5: ...the seating area of the Throttling Plug 33 for damage or erosion If damaged it should be replaced It would be advisable to replace the entire bottom cap assembly Inspect all gaskets and O rings for damage and replace where necessary Assembly When reassembling the valve all internal parts should be clean dry and lightly oiled with refrigerant oil except O rings Apply silicone grease to the O rings ...

Page 6: ...sembly procedure for the A4A pilot pages 4 and 5 When mounting the pilot place the O Rings 50 into the proper grooves and tighten the Cap Screws 49 evenly The ideal tightening torque is 1 1 Kg m 8 ft lbs S6A Modular Solenoid Pilot Figs 10 and 12 This solenoid pilot may be mounted on either Pad 1 or 2 depending on the function desired see pages 2 and 3 Before working on any solenoid pilot make sure...

Page 7: ... operation Make sure that the regulator receives the proper electrical signal where modular pilot solenoids are used Make sure they are same as the power supply Check hand valves in the system to make sure they are open or closed as required and the system is receiving liquid or gas as the case may be Solenoid Coils and Coil Housing The solenoid coils and coil housing identified and described on p...

Page 8: ...rty damaged or frozen Clean or replace Clean strainer shut off flow Diaphragm follower stuck or damged Clean or replace Install follower carefully Piston jammed with excess dirt Remove and polish piston and bore with crocus cloth Clean valve and strainer Throttling plug leaking due to excess Clean or replace If used on liquid check for dirt or damage erosion due to excessive flash gas Reduce flash...

Page 9: ... 5 1 1 4 256 10 1 1 1 2 307 12 1 SW FOR 3 4 216 8 5 2 1 2 331 13 0 3 389 15 3 4 450 17 7 4 450 17 7 PIPE SIZES 1 216 8 5 1 1 2 256 10 1 2 307 12 1 SHOWN 1 1 4 216 8 5 F 1 1 4 300 11 8 1 1 2 364 14 3 WN FOR 3 4 254 10 0 2 1 2 401 15 6 3 478 18 8 4 571 22 5 4 571 22 5 PIPE SIZES 1 261 10 3 1 1 2 304 12 0 2 371 14 6 SHOWN 1 1 4 261 10 3 G 7 8 239 9 4 1 3 8 269 10 6 1 5 8 358 14 1 2 5 8 348 13 7 3 1 8...

Page 10: ...Avail with Kit 2 16 17 19 DiaphragmKit Rge D 200771 1 200771 1 16 19 VCVacuumCartridge Only Avail with Kit 1 Only Avail with Kit 1 Pilot Seat Rge A 202000 1 202000 1 16 19 DiaphragmKit Rge V 202004 1 202004 1 Not A4AO Rge D 202002 1 202002 1 27 Plug Pkg 1 4 NPT 202552 5 202552 5 28 Adapter Only Avail with Kit 1 Only Avail with Kit 1 29 Gasket Only Avail with Kit 1 Only Avail with Kit 1 19 27 28 Ad...

Page 11: ...Avail with Kit 1 16 17 19 200770 1 200770 1 200770 1 200770 1 200770 1 200770 1 17 Only Avail with Kit 2 Only Avail with Kit 2 Only Avail with Kit 2 Only Avail with Kit 2 Only Avail with Kit 2 Only Avail with Kit 2 16 17 19 200771 1 200771 1 200771 1 200771 1 200771 1 200771 1 16 19 Only Avail with Kit 1 Only Avail with Kit 1 202004 1 202004 1 202004 1 202004 1 202000 1 202000 1 202000 1 202001 1 ...

Page 12: ... gaskets plus O Rings If applicable 25 26 29 37 Gasket Kit A4 S4 202112 202112 43 45 3 Indv I Gaskets O Rings Valve Pk g sold pkgd in qtys only as Indicated 29 Gasket Pkg Adapter 202406 5 202406 5 37 O Ring Gasket Pkg Bottom Cap 202384 3 202384 3 43 Gasket Pkg Seal Cap Bottom 202408 12 202408 12 2 Gasket Pkg Seal Cap Top 202408 12 202408 12 45 Gasket Pkg Flange 202079 12 202079 12 4 Packing Pkg St...

Page 13: ...lyAvail with Kit 1 OnlyAvail with Kit 1 OnlyAvail with Kit 1 29 112 200669 1 200673 1 200673 1 200690 1 200676 1 200677 1 7 16 2 19 2 Gasket Kits includes complete set of gaskets plus O Rings if applicable 25 26 29 37 202113 202114 202114 202115 202116 202117 43 45 3 Individual Gaskets 10 Rings and Valve Packing sold and packaged In quantities only as Indicated 29 202407 5 202397 3 202397 3 202396...

Page 14: ... 4 to 2 port Pressure Pilot A2D used on main valve sizes 2 1 2 to 4 port Repair Kits indicated for the A2D2 and A2D are common parts used on the integral pressure pilot mounted on the A4A Series Regulator Repair Parts Kits for A2D2 and A2D Modular Pressure Pilots Spare or Additional A2D2 and A2D Repair Kit Packages Note The following items are included in the above Kits in the exact numbers as req...

Page 15: ... Kit 50 O Ring 2 Also available in package See below 66 Bolts 4 Only Available with Kit 50 66 Bolt O Ring Kit 1 201574 62 Gasket 1 Only Available with Kit 63 Plunger Needle Assembly 1 Only Available with Kit 62 63 Plunger Kit Needle 1 201019 62 Gasket 1 Only Available with Kit 63 Plunger Needle Assembly 1 Only Available with Kit 62 63 Plunger Kit Needle 1 201021 D C only 62 Gasket 1 Only Available...

Page 16: ... Bulletins and Safety Bulletin RSB prior to installation or servicing work Where cold refrigerant liquid lines are used it is necessary that certain precautions be taken to avoid damage which could result from liquid expansion Temperature increase in a piping section full of solid liquid will cause high pressure due to the expanding liquid which can possibly rupture a gasket pipe or valve All hand...

Reviews: