![Parker AC650V Series Product Manual Download Page 77](http://html1.mh-extra.com/html/parker/ac650v-series/ac650v-series_product-manual_3771557077.webp)
12-1
Applications
650V AC Drive
Chapter 12
A
PPLICATIONS
The Default Application
The drive is supplied with 6 Applications, Application 0 to Application 5. Each Application
recalls a pre-programmed structure of internal links when it is loaded.
Application 0 will not control a motor. Loading Application 0 removes all internal links.
Application 1 is the factory default application, providing for basic speed control
Application 2 supplies speed control using a manual or auto setpoint
Application 3 supplies speed control using preset speeds
Application 4 is a set-up providing speed control with Raise/Lower Trim
Application 5 supplies speed control with Run Forward/Run Reverse
Application 6 provides for basic speed control with convenient sequencing over comms.
IMPORTANT:
Refer to Chapter 5: The Keypad – Special Menu Features to reset the drive to factory
default values which are suitable for most applications.
How to Load an Application
In the
menu, go to
and press the
key twice.
The Applications are stored in this menu.
Use the
keys to select the appropriate Application by number.
Press the
key to load the Application.
Application Description
Control Wiring for Applications
The large Application Diagrams on the following pages show the full wiring for push-button
starting. The diagrams on the reverse show the full wiring for single wire starting.
For the minimum connections to make the drive run refer to Chapter 3: "Installing the Drive" -
Electrical Installation; the remaining connections can be made to suit your system.
When you load an Application, the input and output parameters shown in these diagrams default
to the settings shown. For alternative user-settings refer to the Software Product Manual, Chapter
1 "Programming Your Application", available from www.parker.com/ssd
normally open contact (relay)
2-position sw itch
normally open push-button
normally closed push-button
Key to Application Diagrams
Not Stop
Jog
Run
+24V
AOUT1
+10V REF
Feedback
Setpoint
0V
Direction
Reset
Low er
Run
+24V
AOUT1
+10V REF
not used
not used
0V
Raise
Preset 0
Preset Select
Preset Select
Run
AOUT1
+10V REF
Preset Select
+24V
Preset 0
0V
Manual Setpoint
Direction
Select
Manual Run
+24V
AOUT1
+10V REF
Auto Setpoint
0V
Auto Run
Health
Health
Health
Health
Not Stop
Jog
Run
+24V
AOUT1
+10V REF
Feedback
Setpoint
0V
Direction
Health
Manual/Auto
Presets
Raise/Low er
PID
Basic Speed
Control
(default)
APPLICATION 1
APPLICATION 2
APPLICATION 3
APPLICATION 4
APPLICATION 5
Run Reverse
PID Reset
Coast Stop
Run Reverse
Jog
Coast Stop
Run Reverse
Jog
Coast Stop
Unused
Jog
Coast Stop
Run Reverse
Unused
Coast Stop
Terminal
Control
RL1A
RL1B
DIN4/DOUT2
DIN3
DIN1
+24V
AOUT1
+10V REF
AIN2
AIN1
0V
DIN2
DIN7 (ENCB)
DIN6 (ENCA)
DIN5
10k Speed
Setpoint
User Relay
default source = A
V
A
10
9
8
7
6
5
4
3
2
1
RL1A
RL1B
13
12
11
W IRE
SINGLE
STARTING
DEFAULT