![Parker AC650V Series Product Manual Download Page 32](http://html1.mh-extra.com/html/parker/ac650v-series/ac650v-series_product-manual_3771557032.webp)
The Keypad
5-7
650V AC Drive
Password Protection
When activated, an odd-numbered password prevents unauthorised parameter modification by
making all parameters read-only. The local setpoint is not made read-only if an even-numbered
password is used. Password protection is set-up using the
parameter
Steps
ACTIVATE
TEMPORARY DE-ACTIVATION
REMOVE PASSWORD
Actions
Display
Actions
Display
Actions
Display
1
Go to
Press
Try to edit any
parameter with
password activated
Go to
Press
2
Enter new
password using
for example
Enter current
password using
for example
Enter current
password using
for example
3
Press
repeatedly until
top of menu is
reached
, Remote
Setpoint or
Local Setpoint
Press
Original
parameter
displayed,
password
de-activated
Press
Reset to 0000
using
4
Press
to
activate
password
, Remote
Setpoint or
Local Setpoint
A drive will power-up with the last
password status. Temporary de-
activation is lost on power-down.
Press
to
remove
password
Default = 0000, de-activated
Any other value is a password