Parameter Reference
D-75
AC30V series Variable Speed Drive
Sequencing
Parameters::Motor Control::Sequencing
These parameters allow the user of the AC30V to monitor the status and affect the behaviour of the DS402 drive state machine as described in
detail in Appendix B “Sequencing Logic”.
PNO Parameter Descriptions
Local
Local (GKP) Control and/or Reference.
Local Reference
Local Reference from GKP.
App Cmd Word
Control Word from Application (Terminals).
Comms Cmd Word
Control Word from Fieldbus.
Command Word
Monitor (read-only) Control Word updated from the active source.
Status Word
This is the DS402 Status Word
Sequencing State
Drive DS402 Sequencing State.
Switch On Timeout
Time allowed for line contactor to close when entering the Switched On state from Switched Off state. If this time is non-zero, a Line
Contactor trip will occur if the DC Link Voltage remains low until the timeout expires. If the timeout is set to zero, an Under Voltage
trip will occur immediately.
App Reference
Reference from terminals (via. the application)
Comms Reference
Reference from Fieldbus
Summary of Contents for AC30V Series
Page 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Page 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Page 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Page 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Page 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Page 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Page 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Page 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Page 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Page 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Page 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...