D-112
Parameter Reference
AC30V series Variable Speed Drive
PNO
Name
Path(s)
Type
Default
Range
Units
WQ
View
Notes MBus
0558
PMAC Rated Torque
Same as PNO 555
REAL
4.50
0.00 to 30000.00
Nm
ALWAYS
TECHNICIAN 4
01643
0559
PMAC Motor Poles
Same as PNO 555
UINT
10
0 to 400
ALWAYS
TECHNICIAN 4
01645
0560
PMAC Back Emf Const KE
Same as PNO 555
REAL
60.0
0.0 to 30000.0
V
ALWAYS
TECHNICIAN 4
01647
0561
PMAC Winding Resistance
Same as PNO 555
REAL
6.580
0.000 to 50.000
Ohms ALWAYS
TECHNICIAN 4
01649
0562
PMAC Winding Inductance
Same as PNO 555
REAL
20.00
0.00 to 1000.00
mH
ALWAYS
TECHNICIAN 4
01651
0563
PMAC Torque Const KT
Same as PNO 555
REAL
1.00
0.00 to 10000.00
Nm/A ALWAYS
TECHNICIAN 4
01653
0564
PMAC Motor Inertia
Same as PNO 555
REAL
0.00100
0.00000 to 100.00000
kgm² ALWAYS
TECHNICIAN 4
01655
0565
PMAC Therm Time Const
Same as PNO 555
TIME
62.000
0.000 to 10000.000
s
ALWAYS
TECHNICIAN 4
01657
0568
Magnetising Current
Advanced Setup::Motor Control::Induction Motor
Data
Parameters::Motor Control::Induction Motor Data
REAL
1.00
0.00 to 10000.00
A
ALWAYS
TECHNICIAN 4
01663
0569
Rotor Time Constant
Same as PNO 568
TIME
0.100
0.005 to 100.000
s
ALWAYS
ENGINEER
4
01665
0570
Leakage Inductance
Same as PNO 568
REAL
1.000
0.000 to 1000.000
mH
ALWAYS
ENGINEER
4
01667
0571
Stator Resistance
Same as PNO 568
REAL
0.00
0.00 to 100.00
Ohms ALWAYS
ENGINEER
4
01669
0572
Mutual Inductance
Same as PNO 568
REAL
100.00
0.00 to 10000.00
mH
ALWAYS
ENGINEER
4
01671
0591
Local
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 1
01709
0592
Local Reference
Control Screen
Parameters::Motor Control::Sequencing
REAL
0.00
0.00 to 100.00
%
ALWAYS
OPERATOR 4
01711
0610
App Control Word
Parameters::Motor Control::Sequencing
WORD
(bitfield)
0000
0:SWITCH ON
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
15:EVENT TRIGGERED OP
ALWAYS
ENGINEER
2
01747
0611
App Control Word.SWITCH ON
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01749
0612
App Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01751
0613
App Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01753
0614
App Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01755
0618
App Control Word.RESET FAULT
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01763
0623
App Control Word.USE JOG REFERENCE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01773
0624
App Control Word.REVERSE DIRECTION
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01775
0625
App Control Word.AUTO INITIALISE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01777
0626
App Control Word.EVENT TRIGGERED OP
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
ENGINEER
2
01779
0627
Comms Control Word
Parameters::Motor Control::Sequencing
WORD
(bitfield)
0000
0:SWITCH ON
1:ENABLE VOLTAGE
2:NOT QUICKSTOP
3:ENABLE OPERATION
7:RESET FAULT
10:USE COMMS CONTROL
11:USE COMMS REFERENCE
12:USE JOG REFERENCE
13:REVERSE DIRECTION
14:AUTO INITIALISE
15:EVENT TRIGGERED OP
ALWAYS
TECHNICIAN 2
01781
0628
Comms Control Word.SWITCH ON
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01783
0629
Comms Control Word.ENABLE VOLTAGE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01785
0630
Comms Control Word.NOT QUICKSTOP
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01787
0631
Comms Control Word.ENABLE OPERATION
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01789
0635
Comms Control Word.RESET FAULT
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01797
0638
Comms Control Word.USE COMMS CONTROL
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01803
0639
Comms Control Word.USE COMMS
REFERENCE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01805
0640
Comms Control Word.USE JOG REFERENCE
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01807
0641
Comms Control Word.REVERSE DIRECTION
Parameters::Motor Control::Sequencing
BOOL
FALSE
ALWAYS
TECHNICIAN 2
01809
Summary of Contents for AC30V Series
Page 34: ...Installation 4 16 AC30V series Variable Speed Drive Basic Speed Control Wiring...
Page 35: ...4 17 Installation AC30V series Variable Speed Drive APPLICATION 1 AUTO MANUAL CONTROL...
Page 36: ...Installation 4 18 AC30V series Variable Speed Drive Auto Manual Control Wiring...
Page 37: ...4 19 Installation AC30V series Variable Speed Drive APPLICATION 2 RAISE LOWER TRIM...
Page 38: ...Installation 4 20 AC30V series Variable Speed Drive Raise Lower Trim Wiring...
Page 39: ...4 21 Installation AC30V series Variable Speed Drive APPLICATION 3 PRESETS SPEEDS...
Page 40: ...Installation 4 22 AC30V series Variable Speed Drive Presets Speeds Wiring...
Page 41: ...4 23 Installation AC30V series Variable Speed Drive APPLICATION 4 PID CONTROL...
Page 42: ...Installation 4 24 AC30V series Variable Speed Drive PID Control Wiring...
Page 162: ...Sequencing Logic B 2 AC30V series Variable Speed Drive SEQUENCING DIAGRAM...
Page 325: ...E 2 E Plan Library AC30V series Variable Speed Drive Which then brings up the E Plan page...