7. How to set a Parameter value
Page 8
This guide has been produced by The Inverter Drive Supermarket Ltd.
All content, including but not limited to graphics, text and procedures copyright
The Inverter
Drive Supermarket and must not be reproduced or altered without prior written permission.
©
Parker SSD Drives 650 Series Inverter
7.1 Press and hold the “M” (Menu) key for 1 second.
This example demonstrates the steps required to set
parameter 6 (P6) which is motor full-load current.
From the speed reference screen (shown in the
illustration opposite), press and hold the Menu key for
approximately 1 second to access the menu.
7.2 Press the up key to move from Diagnostics to
Parameters.
The display shows “diag” to indicate that the currently
selected menu option is “diagnostics”.
Press the up key to select the parameter menu. The
display will show “par” to indicate that this has been
selected.
7.3 Press the Menu key to access the parameter list.
When the display shows “par”, press the Menu key to
access the parameter list.
7.4 The Parameter List
The display shows P1 to indicate that Parameter 1 is
currently selected.
Use the up and down keys to navigate through the list of
available parameters.
For this example, select P6 (motor full-load current).
Press the Menu key to modify the parameter value.