Product Overview
1-3
514C Product Manual
TECHNICAL SPECIFICATION
General
SPEED CONTROL
Control Action
Closed Loop with Proportional Integral Control and
Adjustable Stability
Speed Feedback
Armature Voltage
Tachogenerator
100% Load Regulation
2 % Typical
0.1 % Typical
Maximum Torque/Speed Range 20:1
100:1
Overload
150% for 60 seconds.
TORQUE CONTROL
Control Action
Closed Loop with Proportional Integral Control.
Accuracy
2 %
Overspeed
Inherent.
Overload
None 100% continuous (consideration must be given
to motor when operating at low speed).
INPUTS / OUTPUTS
Analogue
Setpoint Ramp
0 to ±10V
100 Kohm
Inputs
Positive Trim Setpoint
0 to ±10V
100 Kohm
Negative Trim Setpoint 0 to ±10V
100 Kohm
Current Limit
0 to +7.5V
50 Kohm
Current Demand
0 to ±10V
100 Kohm
Tachogenerator Input
0 to ±350Vdc
220 Kohm
Thermistor /
Microtherm Input
<200 ohm = Normal
>1800 ohm = Overtemperature
5 Kohm
Outputs
Setpoint Ramp
0 to ±10V
5 mA
Analogue Total Setpoint
0 to ±10V
5 mA
Speed
0 to ±10V
5 mA
Current Demand
0 to ±10V
5 mA
Current Meter
0 to ±5V (0 to Ical)
5 mA
Bipolar or Modulus
See SW1/8
+10V Reference
+10V
5 mA
-10V Reference
- 10V
5 mA
Digital
Run
+10 to +24V
100 Kohm
Inputs
Enable
+10 to +24V
100 Kohm
Stall Override
+10
100 Kohm
Digital
Health
+24V
50 mA Source
Outputs
Zero Speed or Setpoint +24V
50 mA Source