![Parker 514C-04 Technical Manual Download Page 17](http://html1.mh-extra.com/html/parker/514c-04/514c-04_technical-manual_3750959017.webp)
Pre-Installation Planning
2-5
514C Product Manual
Function
Terminal
540/1
Terminal
514C
Common
C1
T8/11
Thermistor
C2
T22
Auxiliary Enable
C3
-
+24V
C4
T24
Enable
C5
T20
Maintain
C6
-
Start / Run
C7
T5
Ready Output
C8
-
Zero Speed Output
C9
T23
Drive Operational / Health
C10
T19
+24V
C11
T24
Unused
C12
-
DO NOT USE Pending Change
-
T4
Stall Override
-
T15
Switches
Function
540/1
514C
Speed Calibration
No
Yes
SW1/2
Tachogenerator or Armature Voltage
No
Yes
SW1/3
Zero Output Speed or Setpoint
No
Yes
SW1/4
Current Bipolar or Modulus
Yes
S1
Yes
S1/5
Ramp Isolate
Yes
S3
Yes
SW1/6
Standstill
Yes
S2
Yes
SWQ1/7
Current Demand Output or Current Demand Input
No
Yes
SW1/8
Contactor Dropout on Overcurrent
No
Yes
SW1/9
Standstill Comparator Source
No
Yes
SW1/10
Ramp Rate
Yes
S4
No
Current Calibration
No
Yes
SW2/3/4