Technical Specifications
7-4
506/507/508 - HA389427
Electrical Ratings
Output Ratings with typical armature voltage, Va,
80/90V (160/180V)
(1)
Range selected by built in switches.
(2)
When the controller is energised the dc motor shunt field is
permanently energised. It is the responsibility of the installer
to ensure that this is not detrimental to the long term
reliability of the dc motor.
Parameter
506
507
508
Maximum Armature Output
Current (IA)
(1)
1.5A
3A
3A
6A
6A
12A
Typical Motor Horsepower (Hp)
90V Armature (110/120V AC)
180V Armature (220/240V AC)
1
/
10
1
/
6
1
/
6
1
/
3
1
/
6
1
/
3
1
/
3
3
/
4
1
/
3
3
/
4
3
/
4
2
Typical Motor Power (kW)
90V Armature (110/120V AC)
180V Armature (220/240V AC)
0.07
0.125
0.125
0.25
0.125
0.25
0.25
0.55
0.25
0.55
0.55
1.5
Controller loss (W)
5
10
10
20
20
40
Maximum AC Supply Current
(ls,A rms)
3
4.5
6
9
12
18
Maximum l2t for fusing (A2s)
36
36
80
80
365
365
Maximum form factor (ls/la)
2
1.5
2
1.5
2
1.5
Maximum Field Current
(2)
(If, A dc)
2
Field Voltage (0.9 x Vs) V dc
110/120V AC
220/240V AC
V
90-100
180-200
Adjustment Ranges
*
Range selected by built in switches.
Parameter
506
507
508
Maximum current * (l max, A)
0.25 - 3
0.5 - 6
1 - 12