Installing the 506/507/508
4-9
506/507/508 - HA389427
EMC Connections
Figure 4.5 Wiring Diagram Mains Filter
Product
L1
L2
Grd (PE)
F+
F-
A+
A-
Grd (PE)
Grd (PE)
DC Motor
Screened Cable
Filter
AC Supply
PE
Installation and Set-Up
Warning
Before applying power check:-
Switch Selection
(a) Mains switch set to intended supply voltage,
Left
110/120,
Right
220/240
(b) Personality switches.
SW1
OFF
ON
506
0.25 to 3A
0.5 to 3A
507
0.5 to 3A
1 to 6A
508
1 to 6A
2 to 12A
Speed
Range Maximum Feedback Voltage Range
SW2
SW3
Armature or Tacho
OFF
OFF
15 to 30
ON
OFF
30 to 60
OFF
ON
60 to 120
ON
ON
120 to 180
SW4
OFF
ON
FEEDBACK
TACH
ARMATURE