M10
Press esc to return on
USER SETTINGS MENU
.
Select
BMS
:
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
Th
is Screen appears:
- BMS -
U7 - ADRESS: 001
U8 - BAUDRATE: 9600
Th
e parameters
U7
and
U8
selects the adress fo the supervision.
Press esc to return on the
USER SETTINGS MENU
.
Select
MOISTURE DRAIN:
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
Th
is Screen appears:
- MOISTURE DRAIN -
U9 - MODE: Continue
U10 - TIMED On (s):
U11 - TIMED Off (s): 1
U9 →Mode condensate drain (continue; timed; capacitive);
U10→Time “ON” with timed condensate drain;
U11 →Time “OFF” with timed condensate drain;
Press
Esc
to return on
USER SETTINGS MENU
.
Select
OTHER
:
- User Settings Menu -
DRYER SETTINGS
DATE/TIME
BMS
MOISTURE DRAIN
OTHER
LANGUAGE
Th
is Screen appears:
U12 - BACKLIGHT ON: NO
U13 - Enable Money : NO
U14 - Money : Euro
U15 - Money / KWh : 0.120
U16 - Saving Compared
to Heatless
U2
5.3.3 SERVICE PARAMETER
On
MAIN MENU
select
Service
and press
Enter
to confi rm.
- - -Main Menu - - -
START/STOP
USER SETTINGS
SERVICE
INFORMATION
Th
is Screen appears with the request of a password.
INSERT PASSWORD
000
Th
ese confi guration parameters must not be editable by the customer.
5.3.4 INFORMATIONS
On
MAIN MENU
select
INFORMATION
and press
Enter
to confi rm.
- - -Main Menu - - -
START/STOP
USER SETTINGS
SERVICE
INFORMATION
From this page you can view system information and alarm history.
Select
SYSTEM INFO
and press
Enter
to confi rm:
- - - Informations Menu - - -
SYSTEM INFO
ALARMS HISTORICAL
Using
Up
and
Down
. You can view:
-
Information on cycles times;
’
-
Values input signals:
INPUTS
Pressure 1 (B6) : 04.2
Pressure 1 (B7) : 04.3
Level (B8) : NO WAT:
AD Inlet Temp (B9): 02.6
Thermal Mass (B10): 02.4
- Counter
2014/Gen/24 16.20.20
HOURS COUNTERS
UNIT_ON : 000001 (h)
COMPRESSOR : 000001 (h)
LAST OFF DAY : 00,00.00
S1
-
Information about soft ware
SOFTWARE INFO
SW Release : 10
SW date: 2014/01/20
Bios : 5.00. 20/May/01
Boot : 4.00. 20/May/01
-
Information about bypass
BYPASS
BYPASS STATUS : OFF
OPEN L.SWITCH: Closed
CLOSE L.SWITCH : Open
5.4 Energy saving
5.4.1 ENERGY SAVING ( kWh)
Th
e user can see how the unit is saving in kWh, compared with a similar
machine to be chosen from:
- Heatless
- Heat
Regenerated
- Blower
press the key DOWN one time
on the main menu.
Th
is Screen appears:
ENERGY SAVING
0000073.1
KWh
5.4.2 ENERGY SAVING (money)
Th
e user can see how the unit is saving in “money”.
Press the key DOWN two time
on the main menu.
Th