Installation
Fitting a Radio into an Equipment Cabinet
It is essential that the chosen mechanical installation provides adequate support along the
depth (front to rear) of the unit. The transceiver must not be supported by the front panel;
doing so can cause damage.
The transceiver can be installed on telescopic slides, or on fixed runners, within a standard 483 mm
(19 inch) equipment rack. M4 tapped holes, each 10 mm deep (see Fig 10) are provided on each side of
the equipment to accept the slides. Details of suitable telescopic slides and fixed runners are available
from Park Air.
When fitted in the rack, the transceiver's front panel must be secured to the cabinet’s chassis using four
M6 x 16 mm screws and plastic washers.
Fig 10 Slide Fittings
Caution
Mechanical Support
Front
Panel
399
390.9
378.2
232.2
207.5
152.8
47.0
29.0
41.7
430
88.9
450
All measurements in mm
Summary of Contents for T6TR
Page 1: ...T6TR VHF 50 W Transceiver User Documentation ...
Page 10: ...Back to Transceiver Main Page Intentionally Blank ...
Page 24: ...Back to Transceiver Main Page Intentionally Blank ...
Page 66: ...Back to Transceiver Main Page Intentionally Blank ...
Page 98: ...Back to Transceiver Main Page Intentionally Blank ...
Page 130: ...Back to Transceiver Main Page Fig 9 Processor Module Removal and Refitting Detail PA CN 8 ...
Page 132: ...Back to Transceiver Main Page Fig 11 PA Control Rx RF Module Removal and Refitting Detail ...
Page 133: ...Back to Transceiver Main Page Fig 12 Power Supply Removal and Refitting Detail ...
Page 134: ...Back to Transceiver Main Page Fig 13 PA Module Removal and Refitting Detail ...
Page 136: ...Back to Transceiver Main Page Fig 15 Cooling Fan Removal and Refitting Detail ...