background image

Patio Heater Instructions

 

 

OZGLOW HE 40 Hi/Lo

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS - OPTION B

 

 

 

 

1. 

Select a suitable location and fix the J

 

arm (or straight arm) to the roof structure 
of the building or patio.

 

 

Method of bracketing frame into 
position supplied by installer.

 

 

Ensure arm is straight and level.

 

 

 

 

 

 

 

 

 

 

2. 

Feed 4 core electrical wire (supplied by

 

 

installer) down next to the gas pipe and

 

 

pull through far enough to enable joining

 

 

these wires to the wires on the heater

 

 

head.

 

 

 

 

 

 

3. 

Trim the 4 wires on the heater head to 

a

 

length of approximately 100 mm.

 

 

Enter the heater head into the top of the T 
piece and rotate the head to tighten it onto 
the hex nipple.

 

 

Use an approved thread sealant on these 
joints.  Make  sure  you  finish  with  the 
screw  holes  in  the  heater  base  lining  up 
with the holes in the T piece.

 

 

Use the 4 screws provided to fix the heater 
head to the T piece.

 

 

© PARASOL HEATERS AUSTRALIA 

+61 3 9549 4466 - Head 61 3 9546 6069

 

www.parasolheaters.com.au

 

 

Created on 24/09/2015

 

Page 13 of 18

 

Summary of Contents for OZGLOW HE40

Page 1: ...Patio Heater Instructions OZGLOW HE 40 Hi Lo PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61 3 9546 6069 www parasolheaters com au Created on 24 09 2015 Page 1 of 18...

Page 2: ...d COMPONENTS 7 UNIT CLEARANCE 9 UNIT CLEARANCE PATIO RESTAURANT 10 HEATER SPACING 10 INSTALLATION INSTRUCTIONS OPTION A 11 INSTALLATION INSTRUCTIONS OPTION B 13 POINTS TO REMEMBER 15 LIGHTING INSTRUCT...

Page 3: ...domestic or 90 day commercial limited warranty and are fully serviceable with readily available parts if required Delivery is available throughout Australia and overseas The suspended gas heater model...

Page 4: ...d to the same high low switch the warranty is void The OZGLOW HE 40 Hi Lo patio heater is available in versions for use with either Natural or Propane Gas Gas pressure details and gas type are on the...

Page 5: ...ly supervised when they are in the area of the appliance Clothing or other flammable materials should not be hung from the appliance or placed on or near the appliance Any guard or other protective de...

Page 6: ...be required as necessary Keep this OZGLOW heater free of cobwebs and as dust free as possible If the flame becomes excessively long and yellow or if soot builds up on the emitter mesh turn the heater...

Page 7: ...nging Frame Dimensions MIN 15mm GAS INLET BY INSTALLER 650mm 15mm NOMINAL BORE GAS PIPE or COPPER TUBE Overall height 950mm Overall width 960mm PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61...

Page 8: ...HE 40 Hi Lo DIMENSIONS and COMPONENTS Continued J Arm Dimensions 580mm MIN Straight Arm Dimensions MIN PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 61 3 9546 6069 www parasolheaters com au Cr...

Page 9: ...f the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover Within a partial enclosure that includes an overhead cover and no more tha...

Page 10: ...shown No air heating efficiency is counted on in this installation Illustrates the same patio with a 2 5m high protective wall enclosing the patio Only six heaters are required for warmed air will rem...

Page 11: ...tting supplied to the gas inlet of the heater and point it at 90 degrees to the front of the heater 3 Remove the socket assembly from the frame and screw the top half of this assembly to the heater us...

Page 12: ...he emitter mesh and reflector The red and black wires on the heater are to go to the 24 VAC transformer and the yellow wires are to be run to the high low switch supplied by the installer This applian...

Page 13: ...ough to enable joining these wires to the wires on the heater head 3 Trim the 4 wires on the heater head to a length of approximately 100 mm Enter the heater head into the top of the T piece and rotat...

Page 14: ...ipe All wiring in the heater head is 24 VAC Refer to warnings on page 4 5 When the wires have been joined together feed the wires back up the pipe until they look as shown in this picture 6 Fit the bl...

Page 15: ...person Test fire the heater and check the gas pressure All pressure details are on the data plate or refer to page 6 If the heater cannot be adjusted properly contact Parasol Heaters Australia This ap...

Page 16: ...Heater Turn Power ON To Turn Heater Off Turn Power OFF Caution If heater fails to light turn power OFF for 5 minutes then turn the power ON again PARASOL HEATERS AUSTRALIA 61 3 9549 4466 Head Office 6...

Page 17: ...O The two yellow wires receive 24 VAC power from within the appliance When these wires are joined via a switch the heater is on high fire GAS VALVE ADJUSTMENT SCREWS DIAGRAM Pressure Test Point Low F...

Page 18: ...rned to our factory for repair or replacement parts Parasol Heaters Australia will not cover any expenses involved in the return of a heater for a warranty repair Parasol Heaters Australia Pty Ltd wil...