![Parasol OZGLOW HE40 Installation, Operation And Maintenance Instructions Download Page 6](http://html1.mh-extra.com/html/parasol/ozglow-he40/ozglow-he40_installation-operation-and-maintenance-instructions_3629901006.webp)
Patio Heater Instructions
OZGLOW HE 40 Hi/Lo
GAS TYPE
GAS TYPE
NG
PROPANE
TEST POINT HIGH
0.7 kPa
2.6 kPa
PRESSURE LOW
0.4 kPa
1.2 kPa
INJECTORS
3.10mm
1.75mm
IAPMO GMK
10286
GENERAL MAINTENANCE
This OZGLOW heater should be checked at least once each year by a
qualified service person.
More frequent cleaning may be required as necessary.
Keep this OZGLOW heater free of cobwebs and as dust free as possible.
If the flame becomes excessively long and yellow, or if soot builds up on the
emitter mesh, turn the heater off and call a qualified service person.
If this OZGLOW heater will not light or cannot be adjusted to operate
correctly, contact your local authorised dealer or your local gas authority.