Trouble Shooting 

 

 
 
CAUTION  

Before any maintenance work on the compressor, make sure there is not air inside, under pressure.   
 
Every time you stop the compressor, ALWAYS open the manual drains so as to remove condensate. 
 
Maintenance work on the compressor must always be done with the compressor stopped and disconnected from 
the mains supply. Never forget to open the manual drains, after stopping the compressor. 

 

Especially  when  you  are  planning  to  clean  the  solenoid  valves  (auto  drains  version),  always  turn  off  the  main 
electrical supply.  
 
You must always have in mind, if you disconnect the coil of the solenoid valves, without turning off the electrical 
supply, it will be destroyed immediately!!!

 

 
 

Trouble 

Cause 

Remedy

 

Motor does not start  

Electric circuitry faulty

 

Check power supply fuses or/and 
compressor fuses, terminal 
connections, wire leads.  

Thermal switch enabled

 

Decreased 
performance of the 
compressor 
   

 

1

.Blocked air intake filter   

 

1

.Clean - Replace 

2

.1

st

 stage, 2

nd

 stage or 3

rd

 stage valves, 

are not properly closed 

2

.Check the intermediate pressures 

3

.1

st

 stage, 2

nd

 stage or 3

rd

 stage Piston 

rings worn 

3

.Replace 

4

.Worn cylinders 

4

.Replace 

 

 

5

.Pipes leaking   

5

.Tighten and reseal 

6.

Solenoid valves stuck open

 

6.

Clean - Replace

 

7.

Unstable power supply - voltage

 

7. 

Check power supply fuse box

 

8.

Wrong cable diameter or long cable

 

8.

Check - Replace

 

9.

Interstage safety valves leaking

 

9.

Check - Replace

 

Compressor does not 
attain final pressure 
   

 

 

1

.Condensate drain Valve and / or fittings 

leaking   

1

.Tighten and reseal 

2

.Premature opening of final safety valve 

2

.Clean final safety valve and readjust 

3

. Excessive piston clearance 

3

. Replace and regulate again 

4

. Final Safety valve’s safety lock opens 

prematurely 

4

. Check the intermediate pressures, 

regulate or replace valves 

5.

Interstage safety valves leaking

 

5.

Check - Replace

 

6.

Final stage piston rings worn

 

9.

Check - Replace

 

Interstage Safety 
valves releasing 
pressure 
    

1

.If the 1

st

 stage safety valve is released, 

the 2

nd

 stage valves do not close properly 

1

.Check – replace valves 

2

.If the 2

nd

 stage safety valve is released, 

the 3

rd

 stage valves do not close properly 

2

.Check – replace valves 

Summary of Contents for Typhoon Open 13E

Page 1: ...n Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 1 USER M...

Page 2: ...ort and lifting 10 Electric version 11 Petrol version 12 Cylinder filling procedure 13 Dual pressure filling module 14 Automatic start stop system 15 Condensate drainage 16 5 Maintenance Long period s...

Page 3: ...oduct Fail to observe these instructions may lead to serious injury or even death The manufacturer accepts no liability for damage or injury due to non compliance to all instructions of this manual FO...

Page 4: ...00 320lit m 15 m 3 h 250 lit m 18 19m 3 h 300 320lit m 15 m 3 h 250 lit m Ambient temperature 5 C to 45 C Oil capacity 2 2 lit Speed Rotation 800 900rpm 1100 rpm 1290 1380rpm 1100 rpm 1290 1380rpm 110...

Page 5: ...VOLTAGE Risk of electric shock Maintenance work to be carried out only by a trained electrician DIRECTION OF ROTATION Make sure for the proper direction of rotation USER INSTRUCTIONS Users must read...

Page 6: ...g equipment that must be near the compressors Instructions for safe operation risks Check the unit on the inside and outside on a daily basis in order to make sure it is in good working condition Do n...

Page 7: ...y check tightening of the electrical connections If you replace any cable you must use the same type Decompress all hoses filters pressure tanks and basically the entire unit before you carry out any...

Page 8: ...ion place of the compressor The place must not be burdened by unfavorable environmental conditions toxic substances explosives fumes dirt debris etc 2 Place the compressor in a well ventilated area Ma...

Page 9: ...edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 9 Ventilation Natural v...

Page 10: ...ebsite www paramina compressors com 10 Transport and Lifting Check compressor s center of gravity Do not step under the load Transport with Lifting 1 Spreader beam between lifting ropes 2 Two support...

Page 11: ...lectric box is equipped with a reset button and it is enabled first press the reset button to disable it and then the start button in order to start the compressor 3 Immediately after switching on the...

Page 12: ...he engine turn on the drain switch 2 ENGINE STOP When the final pressure is reached turn the key to position ON so as to stop the compressor and then to position OFF so as to cut the power from the ba...

Page 13: ...or than the one at DIN 200 bar is allowed Use cylinders that correspond to the pressures produced by the compressor All the using filling cylinders must be in accordance with international standards a...

Page 14: ...following the same procedure and fill until the maximum filling pressure Never open the filling hose connector valve unless the cylinder is connected to the filling hose Hose whipping due to pressuri...

Page 15: ...ggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 15 Pressure switches adjustment Auto Stop Pressure s...

Page 16: ...electric versions C Optional equipment in petrol and diesel versions The system consists of two timer controlled condensate drains one after the 2 nd and one after the final stage on the BA filter or...

Page 17: ...the two manual drains During routine operation open both drain valves every 20 minutes 2 nd 3 rd Stage C Option One timer New Versions The system consists of one timer located inside compressor s elec...

Page 18: ...EMERGENCY START TOGGLE SWITCH IMPORTANT NOTE DO NOT USE THIS SWITCH UNLESS YOU HAVE FULLY UNDERSTOOD HOW IT WORKS USE THIS SWITCH ONLY IF BATTERY IS TOTALLY DRAINED OUT Attention This switch deactivat...

Page 19: ...he suction while in operation Do not let the compressor heat up stop its operation Close all valves Wrap the inlet air filter with nylon Cover the compressor with a plastic cover to keep the dust out...

Page 20: ...ective cover for air intake filter inlet hose of petrol and diesel models Belt adjustment Check tension of belts after the first 20 hours of operation and then every 100 hours Pressing in the center o...

Page 21: ...compressor The level should always be at the top of the sight glass leaving a small air bubble at the top of the glass While the compressor is operating the level should be between the minimum and the...

Page 22: ...030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 22 Electric Box lifting for motor replacement Typhoon Open 15E 18E A Unscrew the bolts 1 from both...

Page 23: ...MINA compressors operate at environmental temperatures from 5 0 C to 45 0 C Higher temperatures could cause changes in the quality of breathing air lower temperatures may cause a malfunction CAUTION B...

Page 24: ...artridge connector Place and hold a wrench on the cartridge connector while unscrewing the cartridges 3 Lay a small amount of silicone grease on the o ring of the filter s base If there is a trace of...

Page 25: ...he filter s base If there is a trace of damage on the o ring replace 5 Install the new coalescing cartridge cover on filter s base by fastening it down with your hand 6 Wrap a small amount of Teflon a...

Page 26: ...rs Part Nr Description Qty 208000022 Filter housing 1 208000002 Filter base 1 137000040 AC MS cartridge active carbon molecular sieve 2 137000090 AC MS HP cartridge active carbon molecular sieve hopca...

Page 27: ...210 5575868 email service paramina gr website www paramina compressors com 27 Air Flow Diagram Item Description 1 Air inlet 2 Coalescing cartridge 3 Connector 4 Tube connector 5 Purifier 1 42x180 AC...

Page 28: ...M S cartridges from their protective case Be sure that packaging is not punctured If it is damaged do not use it 6 Lay a small amount of silicone grease on the o ring of the new A C M S cartridge 7 R...

Page 29: ...be connector 8 Clean the inside of the filter housing with a clean cloth 9 Remove the new A C M S cartridges from their protective case Be sure that packaging is not punctured If it is damaged do not...

Page 30: ...137000040 AC MS cartridge active carbon molecular sieve 2 137000090 AC MS HP cartridge active carbon molecular sieve hopcalite 306049631 Coalescing cartridge 1 137800000 Coalescing cartridge Cover 1 2...

Page 31: ...hoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 31 Ai...

Page 32: ...he new A C M S cartridge from their protective case Be sure that packaging is not punctured If it is damaged do not use it 7 Lay a small amount of silicone grease on the o ring of the new A C M S cart...

Page 33: ...Wrap a small amount of Teflon around the thread of the tube connector 11 Screw the cartridge connector cover on the tube connector on top of the coalescing cartridge 12 Clean the inside of the filter...

Page 34: ...100 AC MS HP cartridge active carbon molecular sieve hopcalite 208000031 Connector cartridge 1 127052332 O ring c c connector cartridge 1 208000030 Coalescing connector 1 137800000 Coalescing pre filt...

Page 35: ...of silicone grease on the new o rings and then screw the connector on the new A C M S cartridge 9 Place the new A C M S cartridge in the filter housing and fasten it down by hand on the coalescing co...

Page 36: ...and then screw the connector on the new A C M S cartridge 15 Place the new A C M S cartridge in the filter housing and fasten it down by hand on the tube connector see also drawing nr B 16 Lay a smal...

Page 37: ...mpressors com 37 Pressure auto Release BA Cartridge lifetime BA cartridge lifetime may change as humidity temperature levels change In summer a reduction in service hours is recommended see above char...

Page 38: ...hoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 38 Ai...

Page 39: ...ves X Replace pistons and piston rings X Sintered Filter Interstage Final stage Separator drawing at page 63 6 X clean X replace Service Kit 1000hrs 5 p n 190961500 or190961510 X Service Kit 2000hrs 5...

Page 40: ...en wrench tighten further to the specified number of turns from fingered tight T F F T given in Table Apply sealant lubricant to male pipe threads If PTFE tape is used it should be wrapped 1 1 2 to 2...

Page 41: ...stons and piston rings Date Sign Every Day Check the general condition of the compressor Oil Level all connections for leakage for unconventional operation the auto drains and the color of condensates...

Page 42: ...d Decreased performance of the compressor 1 Blocked air intake filter 1 Clean Replace 2 1 st stage 2 nd stage or 3 rd stage valves are not properly closed 2 Check the intermediate pressures 3 1 st sta...

Page 43: ...cient supply of fresh cooling air 1 Check location Max Ambient temperature under 40 C 2 Intake or outlet valves are not closing properly 2 Check and clean valves Replace if necessary 3 Wrong direction...

Page 44: ...way Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 44 6 Spare Parts Catalog Electric Version 1 3...

Page 45: ...80 bar N O 1 8 3 140000080 Filling hose 1 2m 10L 140000921 Kevlar Filling hose 1 2m 8S option SERVICE KIT PART NUMBER 189900200 O RING PART NUMBER 127052702 1 9 1 190000240 1 st stage intercooler 1 10...

Page 46: ...pc Open 18E 2pcs 2 7 1 V Belt According to compressor s serial number 10 182451921 Cooling fan blades 1 136368001 Flywheel 1 105009002 Fan guard set 2 8 1 122063162 1 st Stage Manometer 1 140004602 1...

Page 47: ...Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 47 Petrol Version Image 3 2 3 5 1 7 11 15 6 19 14...

Page 48: ...Auto drain 3 rd stage 350 bar 12V 3 9b 1 219004552 3 rd Stage Safety valve 250 bar 1 219004522 3 rd Stage Safety valve 350 bar 3 10 1 154122241 Auto drain 2 nd stage 80 bar 12V 3 11 1 104270092 Petro...

Page 49: ...pressors com 49 3 27 2 SERVICE KIT PART NUMBER 189900200 O RING PART NUMBER 127052702 2 140000080 Filling hose 1 2m 10L 2 140000921 Kevlar Filling hose 1 2m 8S 3 28 1 186025102 Air Intake Flexible Pip...

Page 50: ...yway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 50 Diesel Version Image 4 2 1 8 7 10 15 11 1...

Page 51: ...valve 350 bar 4 10 1 104515032 Diesel engine 6 8 kW 4 11 4 128604022 Anti vibration pads 4 12 1 219004572 Pressure Maintaining valve 4 13 1 190000250 2 nd stage intercooler 4 14 1 122063162 1 st Stage...

Page 52: ...According to compressor s serial number 10 182451921 Cooling fan blades 1 136368001 Flywheel 1 105009002 Fan guard set 2 1 211670021 Oil filling plug 3 1 109000032 Exhaust filter 4 1 109460302 Air In...

Page 53: ...hose 1 2m 10L 140000921 Kevlar Filling hose 1 2m 8S 12 1 122063402 3 rd Stage Manometer 400b 1 122063012 Manometer rubber cover 13 1 103030072 Electric Motor 5 5kW 103030052 Electric Motor 4kW 1 1330...

Page 54: ...ece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 54 Optional equipment Item Qty Part Nr Description 1 1 208704200 3 rd stage Condensate se...

Page 55: ...018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 55 Compressor Block...

Page 56: ...01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 56 Drawing 1b...

Page 57: ...n Crosshead 2 nd 3 rd Stage 22 2 211430031 Piston Pin 2 nd 3 rd Stage 23 6 211440031 Piston Pin Lock 24 3 211530031 Crankcase Cylinder Gasket 25 2 211210071 Cylinder 2 nd 3 rd Stage 26 9 192201002 Was...

Page 58: ...ing Discharge Valve 3 rd Stage 55 1 190000272 Valve Head 3 rd Stage 56 1 190000282 Top Cover 3 rd Stage 57 6 193108902 Allen Screw M8x90 58 1 211510051 Bottom Gasket Reed Valve 59 1 211240041 Reed Val...

Page 59: ...Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 59 New Version Typhoon Block Fittings Typh...

Page 60: ...01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 60 Old Version...

Page 61: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 62: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 63: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 64: ...yphoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 64...

Page 65: ...n 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 65 8 Cooling...

Page 66: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 67: ...phoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors com 67 9...

Page 68: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 69: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 70: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 71: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 72: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Page 73: ...anual Typhoon Open 01 2018 edition PARAMINA SA Byway Evaggelistrias str 19300 Aspropirgos Greece Tel 0030 210 5575860 1 Fax 0030 210 5575868 email service paramina gr website www paramina compressors...

Reviews: