When filling is complete, first turn off the cylinder’s valve and then the filling hose connector’s valve and proceed to
air venting using the relief valve on the connector. Finally, safely disconnect the cylinder.
During the filling procedure, cylinder’s temperature will rise. Let it cool down. Pressure will slightly drop. If you
wish, re-connect the cylinder with the filling hose (following the same procedure) and fill until the maximum filling
pressure.
Never open the filling hose connector valve, unless the cylinder is connected to the filling hose. Hose
whipping due to pressurized air can cause serious injury!
Automatic stop system
Standard equipment in all electrical versions.
Optional equipment in petrol and diesel versions.
When the pressure reaches the pre-adjusted final level the compressor stops
automatically {through the pressure switch (1)}. The restart of the compressor
must be done manually.
Max. operating pressure 350 bar.
Dual pressure filling module
Optional equipment.
It controls the pressure through a pressure regulator (1) (0-345 bar outlet pressure) and gives the possibility to the
user to fill 200 and 300 bar cylinders simultaneously.
1
300bar filling
1