TROUBLESHOOTING
TROUBLESHOOTING
11. Panel set /on
Supply light on, all others extinguished.
22. Panel unset / off
Supply and Day light on, (Referred to as Day mode)
44. Panel unset / Day mode.
Alarm and Personal Attack lights flashing,
indicating a Personal Attack alarm has taken
place.
To clear the Audible Alarm, enter
(Master or Limited User code)
This will also clear the LEDs.
If additional Personal Attack buttons are fitted on
the system, reset these immediately.
33. Panel unset / Day mode
Alarm light flashing, indicating an alarm
has taken place.
To view log, enter
- Last event will appear
on 7 segment display. Make a note of zone number
or symbol. Check premises for anything different.
i.e an open door or window. If alarm continues to
go off for no apparant reason contact your alarm
company.
To clear display, enter
To clear alarm light, enter
(Master or Limited User code)
RDOC280 issue1
The table below shows the symbols stored in the event log and their meanings.
Symbol
Meaning
Entry/Exit zone activation. The panel was not unset before
the end of the entry time period.
to
Activation of a programmable zone.
This shows the next event in the log has triggered the alarm
system.
This shows that a zone was omitted and refers to the
number which precedes it in the log.
Tamper fault or sabotage.
Personal attack activation.
Fire alarm activation.
8) Omitting one or more zones
If one or more ‘immediate’ zones are triggered whilst in exit mode a low pitched error
tone will be produced.. If this occurs return the panel to ‘DAY’ mode by entering either
the
Master User or Limited User code. If the log is then viewed any faulty zones will be
displayed as above. First check for any obvious reason for these zones to have
been activated. This may simply be due to a monitored door or window being left
open or a pet being left in a protected area. If the fault cannot be rectified it is
possible to omit faulty zones but this should only be used as a last resort if the
building is to be left unoccupied.
Example:
Set panel (error tone will be heard).
Unset panel (alarm LED will be flashing).
View log
to see which zones are faulty
and investigate fault(s) if possible.
Set panel,
then
If no error tone heard, exit via normal route.
or
If error tone heard:
Enter
Fault tone will stop and Day LED will flash.
then
Enter number(s) of zones to be omitted (1 to 6 ) Max of 5 zones.
Enter
Entry / Exit timer will start again. Exit tone will continue.
then
Exit building by normal route.
N.B
If an Entry / Exit zone has to be omitted and your alarm system includes
Walk-through or Access zones, then the panel cannot be unset without first activating
the alarm. If a zone has been omitted because a fault persists then call engineer.