Latch
The latch facility is designed to be used with intruder detectors fitted with a latch
memory. This feature is very useful when more than one detector has to be wired to a
particular zone as it will show which detectors were triggered if an alarm was
generated. If there has been an alarm and latch memory is used, then when the panel
is reset an LED indication will be given at the relevant detector(s). Resetting of latch
memory requires the panel to be set again for not less than 5 seconds, and then
unset.

Event Log
The Paragon Super  control panel incorporates a memory log of the last 18 alarm
events and is accessible to both Master and Limited Users and Engineer. It will
record Fire, Intruder, Personal Attack and Tamper alarms and also show if any of the
6 alarm zones have been triggered or omitted.
The Engineer can set the clearing of the log for either Engineer-only or both Master
User and Engineer.

Auto Rearm
After an alarm the panel will automatically reset itself when the bell timer has expired.
Any zones which still remain triggered at that time will be omitted automatically.

Walk test
The walk test function allows each of the fullset / partset modes to be checked in
order to verify that all the intruder detectors on the alarm system are functioning
correctly. If the panel is set to either Full set or any of the Part-set modes, then only
the non-omitted zones in that particular set mode will activate the walk test chime.

7

7

LIMITED USER FACILITIES

LIMITED USER FACILITIES

Six keys on the keypad are marked with symbols. These symbols are shown below
followed by how they will be referred to in the following text.

 Shift

 Easy-set

 Fire

 P.A

 Up arrow

 Down arrow

1) Full Setting the panel

Enter

 Limited User Code (Factory set to 5 6 7 8)

By using this method, maximum volume will be heard.

or

By using this method, Entry / Exit Tone volume will be reduced.

9

9

99.

Panel unset / Day mode.
Fault light is on.
Supply light is on at the control panel.
This indicates a Fuse fault and you should contact
your installation company.

10

10.

Panel unset / Day mode.
Supply light is on and Day light is flashing
This indicates that you have started a command
but not finished the sequence. The panel is waiting
for further commands.

Enter

 to escape from command and return to

Day mode.

RDOC280 issue1

 RKP

 RKP

 RKP

 RKP

Enter 

 (Master Code)  to exit.

12.

12. Panel unset / Day mode.

Chime light is on, indicating that the panel is
in Chime mode.

Enter 

 - Chime Light will stay on.

The Paragon Plus will remember its last Set Mode
(Full, 1, 2 or 3). Any zone programmed as
Entry / Exit will chime when triggered.

Enter 

 to terminate feature and clear

Chime light.

11

11. Panel unset / Day mode.

Chime light is flashing, indicating that the panel
is in Walk-test mode.

Enter 

 - Chime Light will flash

Set panel to set mode (Full, 1, 2 or 3) that you
wish to test.

Walk Test circuits.

Summary of Contents for Super

Page 1: ...INSTALLATION COMPANY TEL ADDRESS CONTACT USER INSTRUCTIONS RDOC 280 issue 2 PYRONIX LIMITED JUNE 1995 ...

Page 2: ...PyronixLtd PyronixHouse BraithwellWay Hellaby Rotherham SouthYorkshire England S66 8QY Tel 4401709700100 Fax 4401709701042 1 9 RDOC280 issue1 ...

Page 3: ...eypads Paragon RKPs situated at convenient points around the premises Each keypad has an arrangement of 8 LEDs to show the status of the system and a 7 segment display to show programming data and events held in the event log memory All features are fully programmable and there are three levels of access to the system These are Limited User Master user Engineer The Limited User gives access to the...

Page 4: ...each Set Part set mode System Test Function Optional remote keypads with internal sounders Programmable from any remote keypad Separate Bell and Strobe lamp outputs Zone omit facility on exit NB Your Installation Engineer will have programmed all the system features to ensure easy and convenient day to day use of your system See section 5 Engineer Programmable Zones 4 4 FUNCTIONAL DESCRIPTION FUNC...

Page 5: ...y Exit tone will be heard Leave the protected area by the predetermined Entry Exit route As you trigger Access zones the tone will change temporarily to a repeated low tone When all the zones are clear the Entry Exit tone will continue again until the end of the time out period The panel will then be set The panel will not set if the Entry Exit tone is not heard In this case re enter the building ...

Page 6: ...ble when the front cover has been removed and will only affect the volume of any extension speakers The volume control is overridden when the panel is in an alarm state and should only be adjusted by the Engineer The RKP has it s own volume control A reduced volume tone can be obtained when setting the panel by using the Easy Set functions The volume will be determined by the Engineer when setting...

Page 7: ... Full set or any of the Part set modes then only the non omitted zones in that particular set mode will activate the walk test chime 7 7 LIMITED USER FACILITIES LIMITED USER FACILITIES Six keys on the keypad are marked with symbols These symbols are shown below followed by how they will be referred to in the following text Shift Easy set Fire P A Up arrow Down arrow 1 Full Setting the panel Enter ...

Page 8: ... the next most recent entry will be displayed The event log can be scrolled backwards and forwards using the up and down arrow keys to allow the last 18 events to be viewed To leave this function press the key An error tone will be produced if an attempt is made to scroll outside either end of the event memory 5 5 Panel Unset Day mode Alarm and Fire Lights flashing This event will take place under...

Page 9: ... it in the log Tamper fault or sabotage Personal attack activation Fire alarm activation 8 Omitting one or more zones If one or more immediate zones are triggered whilst in exit mode a low pitched error tone will be produced If this occurs return the panel to DAY mode by entering either the Master User or Limited User code If the log is then viewed any faulty zones will be displayed as above First...

Page 10: ...ed If an incorrect key is entered an error tone will be given and the function ended 3 Changing Master Code Enter then Master User code 2 Bleeps Factory set as 1234 then New Master User code 2 Bleeps then New Master User code 2 Bleeps Errors tones as in 2 above 4 System Test Mode Enter This function performs a number of tests which are listed below The next test is selected by pressing any numeric...

Reviews: