MASTER USER FACILITIES
MASTER USER FACILITIES
The Master User has access to all the Limited User facilities as well as those listed
below.
**The Paragon Super control panel has to be in ‘day’ mode after resetting with the
Master code for these additional features to be accessed.**
1) Resetting alarm LED after an Activation
To clear flashing Alarm LED
Enter
Master User (Factory set as 1234)
or
Limited User (Factory set as 5678)
2) Changing Limited User Code
Enter
then
Master User code - 2 Bleeps (Factory set as 1234)
then
New Limited user code - 2 Bleeps
then
New Limited user code again - 2 Bleeps
The ‘day’ led will flash when this function is entered and an acknowledge tone will be
sounded after each code has been entered. If an incorrect key is entered an error
tone will be given and the function ended.
3) Changing Master Code
Enter
then
Master User code, - 2 Bleeps (Factory set as 1234)
then
New Master User code, - 2 Bleeps
then
New Master User code. - 2 Bleeps
Errors tones as in 2) above.
4) System Test Mode
Enter
This function performs a number of tests which are listed below.
The next test is selected by pressing any numeric key.
To exit test mode press the Shift key again.
Test
1) All LED’s are switched on except the fault LED.
2) The strobe is switched on.
3) The bell is switched on
4) The internal sounder is switched on
1
1
RDOC280 issue1
5) Walk Test Mode
Enter
When the walk test mode is enabled the ‘chime’ LED will flash. If the panel is then full
set or part set each active zone will cause a chime when triggered. This enables all
the zone configurations to be walk tested individually. The walk test mode is cleared
when the panel is unset.