Configuration Options Table
The DTE Configuration screen provides the following options and settings.
Configuration
Option Field
Settings
Description
Electrical Interface
V35
EIA530A
V.35 DCE to DTE interface.
EIA-530A DCE to DTE interface.
Local Loopback
OFF
ON
Local loopback is not active.
Local loopback is active and the TST LED is
on. Local loopback causes any data
received from the DTE to be returned to the
DTE. The clock is locally generated by the
DCE.
TX Timing Source
DTE
DCE
The DTE clock is used for the RTU Transmit
Timing Source.
The DCE generates an internal
synchronous clock for the RTU Transmit
Timing Source.
TX Data Strobe
POSITIVE
NEGATIVE
Clocking uses positive edge of clock.
Clock is inverted to use the negative edge of
the clock.
Save configuration option changes by pressing Enter. The message
Configuration
Updated
appears above HW Model on the bottom left of the screen. The next key
pressed causes the message to disappear.
NOTES:
— The Hotwire 5546 RTU configuration setup is now complete. Disconnect the
Console cable.
— Setting the Electrical Interface option to EIA530A without the proper router
interface connector will result in unexpected errors.