1. BitStorm 1900 IP DSLAM
1-26
BitStorm 1900 Installation and Maintenance Guide
1900-A2-GN20-00
Fan Tray Specifications
The -48V DC fan tray and the 110/220V AC (switch selectable) fan
tray are used with the BitStorm 1900 in EtherLoop applications to
provide forced-air cooling in each chassis. A fan tray is required under
each chassis that houses one or more 10306 or 10224 CO modem cards.
Fan Tray 110/220 V AC
Figure 1-9: Fan Tray 110/220 V AC (Part #: 01-00084-02)
115/230V AC
(Switch Selectable)
FUSE
(2 AMP, 250V AC)
ON/OFF
02-17170
Fan Tray 110/220 V AC Specifications
Operating Temperature
0
o
C to 40
o
C (0
o
F to 104
o
F)
Storage Temperature
-40
o
C to 70
o
C (-40
o
F to 158
o
F)
Certifications
UL 60950, cUL, CE
Power Consumption
105 W
Dimensions
3.5” x 18” x 13”
Filter (See Warning below)
For proper air flow, install the air filter
frame only. DO NOT install an air filter
with the frame.
Cord
IEC 320, 6’
AC Supply Fuse
2 AMP, 250 V AC
Summary of Contents for BitStorm IP DSLAM 1900
Page 12: ...List of Tables viii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...
Page 16: ...About This Document xii BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...
Page 48: ...1 BitStorm 1900 IP DSLAM 1 32 BitStorm 1900 Installation and Maintenance Guide 1900 A2 GN20 00...