AIM2-A2-GZ40-20
May 2005
15
Logging In
Open an NMS window and log on. You must log on as a Superuser in order to
configure the AIM24000.
The default Superuser username is:
superuser
The default Superuser password is:
Password
Both are case sensitive.
Circuit Configuration
From the NMS main window, click on any one of the port LEDs depicted on the
hardware image to invoke the Circuit Configuration screen. The following
parameters may be set on the Circuit Configuration screen.
Circuit Identification
Circuit Identification is a unique and searchable 15-character, alphanumeric,
user-defined identifier used to label each port. If the Circuit ID entered is longer
than 15 characters, it is automatically truncated to 15. Typically, service providers
use a corresponding customer number or circuit ID number from their Operations
Support System (OSS) in order to facilitate troubleshooting.
NOTE: The Circuit Identification field is not yet integrated with any OSS system
and is currently for reference only.
Port Mode
Default: Adaptive
Adaptive – An AIM24000 port set to port mode adaptive will automatically train
up to the best possible speed supported by the AIM24000, the ADSL modem
at the remote end, and the copper cable pair connecting the two.