![Paradyne 1862 User Manual Download Page 61](http://html.mh-extra.com/html/paradyne/1862/1862_user-manual_753817061.webp)
1862 VoIP IAD User’s Guide
Chapter 8
Diagnostics
To access the Diagnostics screen, click on the
Diagnostics
button, which is located on the menu
bar. The Diagnostics screen has two test functions: OAM Loopback and Ping test.
8.1 OAM
Loopback
STEP 1:
Click on the
Diagnostics
button, on the menu bar.
STEP 2:
Click on the
Loopback
tab on the Diagnostics screen.
STEP 3:
Enter the following information to run the OAM loopback:
Flow type:
F5 SEG (Segment to Segment) and F5 ETE (End-to-End). The
SEG
loopback is
from ATUR to DSLAM. The
ETE
loopback is from ATUR to the ISP RAS.
VPI and VCI:
Specify the virtual channel that will run the OAM loopback.
Loopback ID:
Type the loopback pattern for the loopback
STEP 4:
Click on the
Start Loopback
button at the bottom of the screen.