Magellan / Spectra SP
59
MG5000 PCB Layout
Refer to Single Zone
Inputs on page 55
Refer to
AC Power
& Backup Battery
Connections on
page 56.
For the keypad’s zone
configurations, refer to
the
Installer Quick
Menu
. If EOL is enabled:
see section
[706]
option
[2]
. Also refer to Keypad
Zone Connections on
page 55.
AUX Power
Refer to transformer requirements on page 56 for Aux. Power
Output. To connect additional wiring to auxiliary power, use
the red (+) and black (-) keypad connectors. Auxiliary power
will shut down if current exceeds 1.1A. If the auxiliary output
is overloaded and is shut down, you must disconnect all
loads from the output for at least 10 seconds before
reconnecting any load back to the auxiliary output.
To provide maximum lightning protection
we strongly recommend having separate
earth connections for the dialer and zone
ground terminals.
To metallic
enclosure
Ground
clamp
AWG#14 single
conductor solid
copper wire
Cold water
pipe
grounding
The "
BELL
" output will shutdown if
the current exceeds 3A.
Disconnect telephone
line before servicing.
Four pin connector
can be used for quick
installation of a
keypad.
Do not cut, bend or alter
the antennas and ensure
that electrical wires do
not cross over the
antennae, as this may
affect signal reception.
Paradox Memory Key
(PMC-4 PMC-5)
Antennas
"RX" & “TX” LED:
Flashes quickly when
receiving or transmitting RF signals
from wireless devices.
"STATUS" LED:
Flash once every second = Normal
Flashes ON 1 second and OFF 1 second =
Any trouble
Always ON = Panel is using phone line
Fast flash 6 seconds after power up = Installer
lock enabled
This equipment must be installed and maintained
by qualified service personnel only.
For UL and C-UL warnings, refer to the UL and
C-UL Warnings section at the back of the
Reference & Installation Manual.
Used for In-Field Firmware upgrade
through a 307USB Direct Connect
Interface. See Connecting to
WinLoad on page 57 for details.
EBUS and Dialer used with:
VDMP3 plug-in voice module for voice reporting
PCS Series GSM communicator module
Press and hold the RESET
button for five seconds. The
STATUS LED will start
flashing. Within 2 seconds of
this flashing, press the reset
switch again. The panel will
reset to default and restart.
The sum of the
current drawn
from the BELL
and AUX must be
limited to 1.3A (40VA
transformer strongly
recommended).
Exceeding this limit
will overload the
panel power supply
and lead to complete
system shutdown.
Connection for Self-Contained Bell/Siren
Max. number of keypads = 15 keypads
Max. aux. current = 700 mA
Max. distance of bus module from panel = 76m (250 feet)
Max. total run of wire = 230m (750 feet)
Charge LED:
Charging and Battery test LED
* If EOL is enabled: see section
[706]
option
[2]
. For the keypad’s
zone configurations, refer to Installer
Quick Menu on page 65. Also refer
to keypad zone connections on
page 55.