42
Programming Guide
Trouble Display
Press the
[
TBL
]
key to view the Trouble Display. Please note that the keypad can be programmed to emit a
BEEP
every 5 seconds
whenever a new trouble condition has occurred. Press the
[
TBL
]
key to stop the beeping.
To view the sub-menu, press the corresponding key in the main menu.
Main Menu Trouble
Sub-Menu Trouble Menu
[1]
Wireless zone low battery
[1]
to
[32]
Zones in low battery
[2]
Power trouble
[1]
Low/No battery on the control panel
[2]
AC failure on control panel
[3]
Auxiliary overload on control panel
[4]
Wireless keypad AC failure
[5]
Wireless keypad battery failure
[6]
Wireless repeater AC failure
[7]
Wireless repeater battery failure
[8]
Wireless siren AC failure
[9]
Wireless siren battery failure
[3]
Bell trouble
[1]
Bell disconnect on control panel
[2]
Bell overload on control panel
[4]
Communication trouble
[1]
Telephone Line Monitoring on control panel
[2]
Fail to communicate on Monitoring Telephone 1 on control panel
[3]
Fail to communicate on Monitoring Telephone 2 on control panel
[5]
Fail to communicate on voice telephone on control panel
[6]
Fail to communicate with PC on control panel
[7]
Fail to communicate with IP receiver 1 or 2 (GPRS)
[8]
Fail to communicate with IP receiver 1 or 2 (IP)
[9]
GSM no service (GSM network failure)
[10]
IP Module No Service (network failure)
[
STAY
]
GSM RF jamming
[
OFF
]
IP Receiver Unregistered (IP/GPRS)
[5]
Tamper and zone wiring failure
[1]
to
[32]
Zones in tamper and zone wiring failure
[6]
Module tamper trouble
[1]
2WPGM
[2]
Keypad bus
[3]
ZX8 bus module
[4]
RTX3 bus module
[5]
Wireless siren
[7]
Fire loop trouble
[1]
to
[32]
Zones in fire loop trouble
[8]
Timer loss
[9]
Wireless zone supervision loss
[1]
to
[32]
Zones in supervision lost
[
STAY
]
RF jamming trouble
[0 (10)] or [10]
Module supervision loss
[1]
2WPGM
[2]
Keypad bus (Panel reset will not clear this trouble, clear it in section [955])
[3]
ZX8 bus module
[4]
RTX3 bus module
[5]
Wireless keypad
[6]
Wireless repeater
[7]
N/A
[8]
VDMP3
[9]
PCS Series (GPRS)
[10]
IP100
[
STAY
]
Wireless siren
[16]
Keypad fault (K32 / K32RF / K37 / K35 only)
[17]
Upgrade panel to V3.2 or higher (K37 only)
[
SLEEP
]
Keypad fault (K636 / K10V/H only)
Summary of Contents for MG5050
Page 71: ......